Schneider Schneider EasyLogic EM6459H VAF PF Meter · CONZERV EM6459H VAF PF DPM NO COM CL 1.0 · METSEEM6459HCL10NC · METSEEM6459HCL10NC
Rated current5 A
Ingress protectionIP51 front:· IP30 body:
Reference standardIEC 61010-1:ed. 3
Net weight0.3 kg
BrandSchneider
Brand SKUMETSEEM6459HCL10NC
ELINEFPDCGK7JG
Sold asPer pc
RangeEasyLogic
Width96 mm
SignalVoltage (impedance 5 MOhm)4 x · Current 0.005...10 A (impedance 0.3 MOhm)6 x
MaterialPolycarbonate
StandardsIEC 61010-1:ed. 3 · UL 61010-1:ed. 3
fixing modeBy clamp
Display type7 segments LED
Product nameEasyLogic EM64XXH NC
Metering typeFrequency · Phase currents · Power factor and displacement PF (signed, four quadrant) · Unbalance current · Percentage of load · Calculated neutral current · Unbalance voltage · Rotation speed · Average voltage Vavg · Average current Iavg · Voltage U21, U32, U13, V1, V2, V3
Mounting modeFlush-mounted
Sampling rate32 samples/cycle
Display colourRed
Display digits12 digit(s) - 14.2 mm in height
type of network3P · 1P + N · 3P + N · 2P · 2P + N
Demand intervals1 s
Flame retardanceV-0 conforming to UL 94
Local signallingGreen LED: activity · Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Mounting supportFramework
Counter functionsPower interruption · ON hour counting · Power outage counting
Device short nameEM6459H
Network frequency50 Hz · 60 Hz
Number of outputs0
Tightening torqueCurrent circuit: 0.9…1 N.m Philips No 2 screwdriver · Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver · Control circuit: 0.9…1 N.m Philips No 2 screwdriver
Device applicationPower monitoring · Power factor control · Load control
Provided equipmentInstallation guide
[In] rated current5 A · 1 A
Measurement current5…6000 mA
Measurement voltage46…277 V AC 50...60 Hz between phase and neutral · 80…480 V AC 50...60 Hz between phases · 277…999000 V AC 50...60 Hz with external VT
Type of measurementCurrent · Voltage · Frequency · Power factor · RPM
Measurement accuracyFrequency +/- 0.05 % · Power factor +/- 0.01 · Current +/- 1 % · Voltage +/- 1 %
Measurement categoryCategory III 35…480 V
Type of installationIndoor installation
Communication of dataRevolution speed · All counters · Percentage of load · Reading of measurements
Installation categoryIII
Wire stripping lengthCurrent circuit: 3.68 mm · Voltage circuit: 7 mm · Control circuit: 7 mm · Communication: 7 mm
Product certificationsCE conforming to IEC 61010-1 · CULus conforming to UL 61010-1 · CULus conforming to CSA C22.2 No 61010-1 · C-Tick
Connections - terminalsCurrent circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) · Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) · Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
Tamperproof of settingsProtected by access code
Messages display capacity3 fields of 4 characters
Product or component typeVAF PF meter
[Us] rated supply voltage44...277 V AC 45...65 Hz · 44...277 V DC
Electrical insulation classClass II
Frequency measurement range45…65 Hz
Maximum power consumption in W2 W at 240 V
Maximum power consumption in VA4 VA at 240 V between phase and neutral
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.