Siemens Sentron 3WT8 ACB 3200 A · 3 Pole · 66 kA · Manual Fixed · Overload · Short Circuit & Earth Fault · 3WT8322-6AA00-0AA23WT8322-6AA00-0AA2↓ 40% off
BrandSiemens
CategorySwitchgear
SpecificationAir circuit breaker (ACB) · 3WT8
Brand SKU3WT8322-6AA00-0AA2
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Siemens· In stock
Visit the Siemens store

Siemens Sentron 3WT8 ACB 3200 A · 3 Pole · 66 kA · Manual Fixed · Overload · Short Circuit & Earth Fault · 3WT8322-6AA00-0AA2

$13,627.77/pc-40%
$22,712.95
Wholesale · 15+ units
$12,946.38 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$13,627.77 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $12,946.38/pc on this product, applied automatically

Siemens Sentron 3WT8 ACB 3200 A (article 3WT8322-6AA00-0AA2) is a air circuit breaker (acb) from Siemens, 3WT8 series, sold by Elume with a GST invoice and pan-India delivery. Key data: manufacturer product name fixed-mounted circuit breaker 3-pole, size 2 In=3200A to 500V, 50/60Hz AC Icu=66kA at 500V with mechanical lockout device with tripped signaling switch with tripped indicators Overcurrent release ETU37WT LSING Setting range according to FS with display With manual operating mechanism with memory with mechanical calling without 1st auxiliary release without 2nd auxiliary release With door sealing frame, ampere/current rating 3200 A, breaking capacity icu 66 kA, no. of poles 3 Pole, tripping type Electronic / Microprocessor, protection type O/L S/C & E/F, operating type Manual Fixed, rated voltage (v) 500V AC. Priced at the Siemens India list price of 2026 (MRP before GST Rs 13,25,920), GST included in the price shown.

As published by Siemens. Verify critical parameters against the datasheet before specifying.
Siemens Siemens Sentron 3WT8 ACB 3200 A · 3 Pole · 66 kA · Manual Fixed · Overload · Short Circuit & Earth Fault · 3WT8322-6AA00-0AA2 · 3WT8322-6AA00-0AA2
Device typeAir circuit breaker (ACB)
Series3WT8
Poles3P (TP)
Rated current3200 A
Breaking capacity66 kA
Current rating3200 A
Reference standardIS/IEC 60898-1
BrandSiemens
Brand SKU3WT8322-6AA00-0AA2
ELINEFMKP6793G
Sold asPer pc
No. Of Poles3 Pole
Tripping TypeElectronic / Microprocessor
Operating TypeManual Fixed
Protection TypeO/L S/C & E/F
Rated Voltage (V)500V AC
Ampere/Current Rating3200 A
Breaking Capacity Icu66 kA
Manufacturer Product Namefixed-mounted circuit breaker 3-pole, size 2 In=3200A to 500V, 50/60Hz AC Icu=66kA at 500V with mechanical lockout device with tripped signaling switch with tripped indicators Overcurrent release ETU37WT LSING Setting range according to FS with display With manual operating mechanism with memory with mechanical calling without 1st auxiliary release without 2nd auxiliary release With door sealing frame
Ratings as published by Siemens (Siemens spec table; eleczo.com listing; Elume). Verify critical parameters against the datasheet before specifying.
Other Siemens ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When is an ACB used instead of an MCCB?

ACBs are used for very high currents, typically 630A up to 6300A, mostly as transformer or main LT panel incomers and bus couplers. They offer high short-time withstand (Icw), advanced releases and maintainability that MCCBs usually do not; both are covered by IS/IEC 60947-2.

What is the difference between fixed and draw-out ACB?

A fixed ACB is bolted directly into the panel, while a draw-out ACB sits in a cradle and can be racked out for testing or maintenance without disturbing the busbars. Draw-out is preferred for main incomers and critical supplies where quick replacement and safe isolation matter.

What is EDO and MDO in an ACB?

MDO (manually operated draw-out) is closed and opened by hand, while EDO (electrically operated draw-out) has a motor and closing/shunt coils for remote operation, auto changeover with DG sets and synchronising schemes. Choose EDO if the ACB will be part of an automatic transfer or SCADA/BMS system.

How do I select the ACB rating for my transformer?

As a rule of thumb, the incomer ACB is rated slightly above the transformer's full-load LT current (about 1.39A per kVA at 415V, so a 1000 kVA transformer needs roughly 1400A, usually a 1600A ACB). The breaking capacity must also exceed the transformer's LT fault level; a qualified electrical engineer should confirm the selection.

Does an ACB need regular maintenance?

Yes. ACBs need periodic inspection of contacts, arc chutes, mechanism lubrication and release testing as per the manufacturer's maintenance schedule, typically at least once a year or after a major fault trip. Maintenance should only be done by trained personnel with the ACB racked out and isolated.