🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand CTX³ 3 Pole Contactor · 9 A AC-3 · 25 A AC-1 · Coil 24 V= · 1 NO + 1 NC · 416081416081↓ 26% off
BrandLegrand
CategorySwitchgear
Specification9 A AC-3 · 25 A AC-1 · Coil 24 V= · 1 NO + 1 NC
Brand SKU416081
AvailabilityOn order · 2 to 3 weeks
Delivery8 to 15 business days after dispatch
Legrand· On order, 2 to 3 weeks
Visit the Legrand store

Legrand CTX³ 3 Pole Contactor · 9 A AC-3 · 25 A AC-1 · Coil 24 V= · 1 NO + 1 NC · 416081

$39.43/pc-26%
$53.28
Wholesale · 15+ units
$37.45 /pc
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Legrand for you once you place the order.
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$39.43 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $37.45/pc on this product, applied automatically

3-pole contactors CTX³ 22 - 9 A - 24 V= - 1 NO + 1 NC - screw terminals. Rating 9A (AC-3) for the switching of 3-ph motors up to 4 kW (415V). Resistive loads up to 25A (AC-1).

  • 1NO + 1NC auxiliary contacts. NC auxiliary contact meets the definition of mirror contact according to IEC 60947-4-1 standard. Can be equipped with all Legrand CTX3 auxiliaries and accessories.
  • Screw terminals capacity: Power 2 x 1mm² to 6mm² / Coil 0,75mm² to 2,5mm² / Aux. Circuit 0,75mm² to 2,5mm²
  • Endurance: up to 15 million mechanical operations and 2,5 million electrical operations. Number of operation cycles (AC-3) per hour : 1800.
As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand CTX³ 3 Pole Contactor · 9 A AC-3 · 25 A AC-1 · Coil 24 V= · 1 NO + 1 NC · 416081 · 416081
SeriesCTX³
Operational current (Ie)9 A (AC-3)
Reference standardIEC 60947-4-1
Warranty18 months from the date of shipment or 12 months from the date of installation
Country of originSouth Korea
Power4 kW
Auxiliary contacts1 NO + 1 NC
Coil / control supply24 V DC
Device typeMiniature circuit breaker (MCB)
Current rating9 A
BrandLegrand
Brand SKU416081
ELINEFF4DCH2CP
Sold asPer pc
Ratings as published by Legrand (legrand.co.in; price list). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet