🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider EasyPact CVS630F MCCB · 4P · 630 A · 70 kA · ETS 6.3 · LV563630LV563630↓ 40% off
BrandSchneider
CategorySwitchgear
Specification4P · 630 A · 70 kA · ETS 6.3
Brand SKULV563630
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider EasyPact CVS630F MCCB · 4P · 630 A · 70 kA · ETS 6.3 · LV563630

Breaking: 70 kA
$1,435.22/pc-40%
$2,392.02
Wholesale · 15+ units
$1,363.46 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$1,435.22 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCCB
FP (4 pole)
630 A
-
70 kA
$1,435.22 /pc
Viewing above ↑
MCCB
FP (4 pole)
630 A
-
70 kA
$1,277.07 /pc
MCCB
FP (4 pole)
630 A
-
70 kA
$1,612.91 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $1,363.46/pc on this product, applied automatically

Schneider EasyPact CVS630F MCCB · 4P · 630 A · 70 kA · ETS 6.3 from Schneider Electric.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider EasyPact CVS630F MCCB · 4P · 630 A · 70 kA · ETS 6.3 · LV563630 · LV563630
Poles4P (FP)
Rated current630 A
Breaking capacity70 kA
Ingress protectionIP40
Reference standardEN 60947-2
Net weight2.05 kg
Device typeMiniature circuit breaker (MCB)
Current rating630 A
BrandSchneider
Brand SKULV563630
ELINEF3K26KCR9
Sold asPer pc
RangeEasyPact
Control typeToggle
Network typeAC
Mounting modeFixed
Thermal memory20 minutes before and after tripping
Trip unit nameETS 6.3
Protection typeInstantaneous short-circuit protection · Short time short-circuit protection · Ground fault protection · Overload protection (long time)
Connection pitch45 mm
Mounting supportBackplate
Neutral positionLeft
Trip unit rating630 A at 40 °C
Device short nameCVS630F
Network frequency50/60 Hz
Poles description4P
Upside connectionFront
Device applicationDistribution
[In] rated current630 A at 40 °C
Downside connectionFront
Trip unit technologyElectronic
Utilisation categoryCategory A
Electrical durability4000 cycles 415 V In conforming to IEC 60947-2 · 8000 cycles 415 V In/2 conforming to IEC 60947-2
Mechanical durability15000 cycles
instantaneous pick-up1.5...11 x In Easypact CVS630
Breaking capacity codeF
Product or component typeCircuit breaker
Suitability for isolationYes conforming to EN/IEC 60947-2
Protected poles description3D · 3D + N/2 · 4D
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Trip unit protection functionsLSIG
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-2
[tsd] short-time delay pick-up0…0.4 s
Long time delay adjustment typeAdjustable
Short-time delay adjustment typeAdjustable
Long time pick-up adjustment range250...630 A
Ground-fault pick-up adjustment typeAdjustable
Long time pick-up adjustment type IrAdjustable
[Ics] rated service breaking capacity70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 32 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[tr] long-time delay adjustment range15…400 s at 1.5 x Ir · 0.35…11 s at 7.2 x Ir · 0.5…16 s at 6 x Ir
Short-time pick-up adjustment type IsdAdjustable
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Instantaneous pick-up adjustment type IiAdjustable
[Isd] short-time pick-up adjustment range1.5...10 x Ir
Ground-fault time delay adjustment type -tgAdjustable
[tg] ground-fault time delay adjustment range0…0.4 s
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

What breaking capacity does this MCCB have?

This MCCB has a breaking capacity of 70 kA. It must be higher than the prospective short-circuit current at the point of installation, which depends mainly on the transformer size and cable length from it.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet