Schneider Acti9 xC60 MCB · 3P · 32 A · D curve · A9N3P32DGNA9N3P32DGN↓ 40% off1 / 3
BrandSchneider
CategorySwitchgear
Specification3P · 32 A · D curve
Brand SKUA9N3P32DGN
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 xC60 MCB · 3P · 32 A · D curve · A9N3P32DGN

Rating: 32 A
Curve: D curve
Poles: 3P
$33.35/pc-40%
$55.57
Wholesale · 15+ units
$31.68 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$33.35 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
TP
32 A
D
-
$33.35 /pc
Viewing above ↑
MCB
TP
32 A
D
10 kA
$21.99 /pc
MCB
TP
32 A
D
-
$27.49 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $31.68/pc on this product, applied automatically

This Acti9 xC60 is a low voltage biconnect miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles and 32A In rated current with C tripping curve. The rated short circuit breaking capacity is up to 10000A at 380VAC - 415VAC conforming to IS/IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. The presence of the green strip guarantees physical opening of the contacts. It allows operations to be performed on the downstream circuit in complete safety. Mechanical durability goes up to 20000 cycles and electrical durability goes up to 20000 cycles. The Ui rated insulation voltage is 500VAC. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail or Vertical Fishbone Busbar for modular installation. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is white (RAL9003) According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 85°C.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 xC60 MCB · 3P · 32 A · D curve · A9N3P32DGN · A9N3P32DGN
Poles3P (TP)
Rated current32 A
Trip curveD curve
Ingress protectionIP20
Reference standardIS/IEC 60898-1
Net weight0.31 kg
ColourWhite
Device typeMiniature circuit breaker (MCB)
Current rating32 A
BrandSchneider
Brand SKUA9N3P32DGN
ELINECP2CMGGH3
Sold asPer pc
Depth77.5 mm
RangeActi9
Width54 mm
Height85 mm
StandardsIS/IEC 60898-1
Curve codeD
9 mm pitches6
Control typeToggle
Network typeAC
Product nameXC60
Mounting modeClip-on
Tropicalisation2 conforming to IEC 60068-1
Limitation class3 conforming to IS/IEC 60898-1
Local signallingON/OFF indication
Mounting support35 mm DIN rail
Pollution degree3
Range of productActi9
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 · 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Device short namexC60
Network frequency50/60 Hz
Poles description3P
Relative humidity95 % at 55 °C
Tightening torque3.5 N.m
Device applicationDistribution
[In] rated current32 A
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Electrical durability10000 cycles
Mechanical durability20000 cycles
Product compatibilityC60 accessories · C60 auxiliary
Wire stripping length13 mm for top or bottom connection
Connections - terminalsBiconnect (bottom) · Tunnel type terminals (bottom) 25 mm² flexible · Tunnel type terminals (bottom) 35 mm² rigid
IP degree of protectionIP20
Magnetic tripping limit10...14 x In
Earth-leakage protectionSeparate block
Number of protected poles3
Product or component typeMiniature circuit-breaker
Contact position indicatorYes
[Ue] rated operational voltage220...240 V AC 50/60 Hz · 380...415 V AC 50/60 Hz
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-30…70 °C
Comb busbar and distribution block compatibilityTop: YES
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

What curve is this MCB?

The tripping curve of this MCB is D curve. C is the general-purpose choice for mixed household loads, B suits lighting and resistive circuits, and D is for equipment with heavy inrush current.

What current is this MCB rated for and what wire should I use with it?

This MCB is rated 32 A. As a rough guide for copper wiring in Indian homes, 6-10A usually goes with 1.5 sq mm lighting circuits, 16A with 2.5 sq mm socket circuits and 20-32A with 4-6 sq mm, but cable length and installation method matter, so have a licensed electrician confirm.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.