🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider Acti9 Switch Disconnector · 4P · 125 A · A9S4P125A9S4P125↓ 40% off
BrandSchneider
CategorySwitchgear
SpecificationActi 9 Isolator xSW 4P 125A 2.5kA 415V AC
Brand SKUA9S4P125
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 Switch Disconnector · 4P · 125 A · A9S4P125

$66.65/pc-40%
$111.08
Wholesale · 15+ units
$63.30 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$66.65 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
ISOLATOR
FP (4 pole)
125 A
n/a
2.5 kA
$66.65 /pc
Viewing above ↑
ISOLATOR
FP (4 pole)
125 A
n/a
-
$21.21 /pc
ISOLATOR
FP (4 pole)
125 A
n/a
-
$23.56 /pc
ISOLATOR
FP (4 pole)
125 A
n/a
-
$26.17 /pc
ISOLATOR
FP (4 pole)
125 A
n/a
-
$33.83 /pc
ISOLATOR
FP (4 pole)
125 A
n/a
-
$52.06 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $63.30/pc on this product, applied automatically

This Acti9 xSW is a modular and reliable switch disconnector. it is a 4 poles, rated current is 125A, and o poleserating voltage is 415VAC. Electrical endurance goes up to 30000 cycles, and Mechanical endurance goes up to 300000 cycles. The operating temperature is -20°C to +50°C. The storage temperature is -40°C to +70°C. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. Total number of 18 mm modules 4. This switch disconnector is used for control. This product is compliant with EN/IEC 60669-1,EN/IEC 60947-3.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 Switch Disconnector · 4P · 125 A · A9S4P125 · A9S4P125
Poles4P (FP)
Rated current125 A
Reference standardIEC 60669-1
Device typeSwitch disconnector (isolator)
Current rating125 A
Breaking capacity2.5 kA
BrandSchneider
Brand SKUA9S4P125
ELINEC9GD7GDKP
Sold asPer pc
RangeActi9
StandardsIEC 60669-1 · IEC 60947-3
Pollution degree3
Range of productISW 40...125
Poles description4P
Tightening torque3.5 N.m
Device applicationIsolation
Product destinationDistribution board
Utilisation categoryAC-22A
Product or component typeIsolator
Total number of 18 mm modules4
[Ui] rated insulation voltage500 V
[Ie] rated operational current125 A at 415 V AC
Ambient air temperature for operation-30…70 °C
[Uimp] rated impulse withstand voltage6 kV
[Icw] rated short-time withstand current1.5 kA during 1 s at 415 V
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between an isolator and an MCB?

An isolator (switch-disconnector) only switches the circuit on and off and does not trip on overload or short circuit, while an MCB provides protection. Isolators are used as main switches in DBs or near equipment for safe maintenance, and must be backed by a suitable MCB, MCCB or fuse.

Can I use an isolator as the main switch in my DB?

Yes, a DP isolator for single-phase or 4P isolator for three-phase is commonly used as the DB incomer, provided protection is given upstream (by the meter-side fuse or MCB) and on each outgoing circuit. Its current rating should be equal to or higher than the upstream protection rating.

Is this isolator safe to switch on load?

Switch-disconnectors to IS/IEC 60947-3 are rated for switching under load according to their utilisation category, such as AC-22 for mixed resistive and inductive loads or AC-23 for motor loads. Check the category on the product before using it to switch motors directly.

2 pole or 4 pole isolator - which one do I need?

Use 2 pole for single-phase supply (phase and neutral) and 4 pole for three-phase supply with neutral, so all live conductors are disconnected during maintenance. A 3 pole isolator is used where no neutral is switched, such as some motor feeders.

Can an isolator be locked off for maintenance?

Many isolators and rotary switch-disconnectors have a padlocking provision in the OFF position so no one can switch them on while work is in progress. Check for the lock-off feature if it is needed for your site's safety procedures.

No reviews yet