Schneider Schneider EasyLogic EM6433H Energy Meter · 1P/3P · 5 A · Class 1 active energy · Class 2 re · METSEEM6433HCL10RS · METSEEM6433HCL10RS
Rated current5 A
Ingress protectionIP51 front:· IP30 body:
Reference standardIEC 61010-1:ed. 3
Net weight0.3 kg
BrandSchneider
Brand SKUMETSEEM6433HCL10RS
ELINEC6F9RG9JJ
Sold asPer pc
RangeEasyLogic
SignalCurrent 0.005...10 A (impedance 0.3 MOhm)6 x
MaterialPolycarbonate
fixing modeBy clamp
Display type8 segments LED
Product nameEasyLogic EM64XXH RS
Metering typeActive power P, P1, P2, P3 · Average current Iavg · Reactive power Q1, Q2 · Phase currents · Apparent power S, S1, S2, S3 · Calculated neutral current · Power factor and displacement PF (signed, four quadrant) · Unbalance current · Active, reactive, apparent energy (signed, two quadrant)
Mounting modeFlush-mounted
Sampling rate32 samples/cycle
Accuracy classClass 1 active energy conforming to IEC 62053-21 · Class 2 reactive energy conforming to IEC 62053-24
Data recordingEnergy consumption logs
Display colourRed
Display digits12 digit(s) - 14.2 mm in height
Output voltage5...40 V DC@20 mA
type of network3P · 2P + N · 1P + N · 2P · 3P + N
Demand intervals1 s
Flame retardanceV-0 conforming to UL 94
Impulse duration20 ms
Local signallingGreen LED: activity · Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Mounting supportFramework
Device short nameEM6433H
Network frequency60 Hz · 50 Hz
Number of outputs1 pulse
Device applicationPower monitoring
Provided equipmentInstallation guide
[In] rated current5 A · 1 A
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50...60 Hz between phases · 35…277 V AC 50...60 Hz between phase and neutral · 277…999000 V AC 50...60 Hz with external VT
Type of measurementCurrent · Active power · Active energy
Measurement accuracyCurrent +/- 0.5 % · Power +/- 0.5 % · Frequency +/- 0.05 % · Reactive power +/- 2 % · Active power +/- 0.5 % · Apparent power +/- 0.5 % · Active energy +/- 0.5 % · Apparent energy +/- 0.5 %
Measurement categoryCategory III 35…480 V
Type of installationIndoor installation
Communication of dataReading of measurements
Installation categoryIII
Connections - terminalsCurrent circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) · Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) · Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) · Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s)
Tamperproof of settingsProtected by access code
Messages display capacity3 fields of 4 characters
Product or component typeEnergy meter
[Us] rated supply voltage44...300 V AC 45...65 Hz · 44...300 V DC
Communication port supportScrew connector: RS485
Communication port protocolModbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2-wire, insulation 2500 V
Electrical insulation classClass II
Frequency measurement range45…65 Hz
Maximum power consumption in W2 W at 240 V
Maximum power consumption in VA4 VA at 240 V between phase and neutral
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.