Lauritz Knudsen DU100H MCCB · 3P (TP) · 80 A · 30 kA · Thermal-magnetic release · CM97894OOJ2CM97894OOJ2↓ 16% off
BrandLauritz Knudsen
CategorySwitchgear
SpecificationMCCB · 3P (TP) · 80 A · 415 V AC
Brand SKUCM97894OOJ2
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Lauritz Knudsen· In stock★4.0(1)
Visit the Lauritz Knudsen store

Lauritz Knudsen DU100H MCCB · 3P (TP) · 80 A · 30 kA · Thermal-magnetic release · CM97894OOJ2

Poles: 3 Pole
Current Rating: 80A
$96.60/pc-16%
$114.93
Wholesale · 15+ units
$91.76 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$96.60 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $91.76/pc on this product, applied automatically

Lauritz Knudsen DU100H MCCB · 3P (TP) · 80 A · 30 kA · Thermal-magnetic release is an MCCB from Lauritz Knudsen. Key ratings: Poles 3P (TP), Rated current 80 A, Breaking capacity 30 kA, Release Thermal-Magnetic, Rated voltage 415 V AC.

  • Phase barriers supplied with the breaker
  • Wide range of snap-fit internal and external accessories
  • Spreader terminals available for larger cables
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen DU100H MCCB · 3P (TP) · 80 A · 30 kA · Thermal-magnetic release · CM97894OOJ2 · CM97894OOJ2
Device typeMoulded case circuit breaker (MCCB)
Poles3P (TP)
Rated current80 A
Breaking capacity30 kA
Rated voltage415 V AC
ReleaseThermal-Magnetic
Current rating80 A
Reference standardIS/IEC 60898-1
BrandLauritz Knudsen
Brand SKUCM97894OOJ2
ELINE9MRFHC9JM
Sold asPer pc
Ratings as published by Lauritz Knudsen (Elume catalogue; Product name; Lauritz Knudsen smartshop). Verify critical parameters against the datasheet before specifying.
Other Lauritz Knudsen ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Thermal-magnetic or microprocessor release - which one do I need?

The release type of this MCCB is Thermal-Magnetic. Thermal-magnetic releases are simpler and suit most feeders, while microprocessor (electronic) releases give finer adjustable settings, earth fault protection options and better selectivity for main incomers and critical loads.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.