🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider TeSys Component · TeSys Vario · emergency stop switch disconnector · 40 A · on door · VCF2VCF2↓ 40% off
BrandSchneider
CategoryIndustrial Control
SpecificationTeSys Vario · emergency stop switch disconnector · 40 A · on door
Brand SKUVCF2
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider TeSys Component · TeSys Vario · emergency stop switch disconnector · 40 A · on door · VCF2

$74.00/pc-40%
$123.34
Wholesale · 15+ units
$70.30 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$74.00 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $70.30/pc on this product, applied automatically

TeSys Vario switch disconnector for door mounting, 3 poles, 40A/690V, for motor switching applications up to 15kW@400V AC-23. Complete unit composed of a switch body V2, a red handle with yellow 60x60mm front plate KCF1PZ. Intended for main and emergency stop switch disconnecting usage. Padlockable handle, for 3 padlocks (to be ordered separately). Handle with 4 screws fixing on door, ensuring IP65 to the mounting. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider TeSys Component · TeSys Vario · emergency stop switch disconnector · 40 A · on door · VCF2 · VCF2
Poles3P (TP)
Rated current40 A
Reference standardIEC 60947-3
BrandSchneider
Brand SKUVCF2
ELINE9MJR9FC2H
Sold asPer pc
RangeTeSys
Width60 mm
Height74 mm
Marking0 - 1
StandardsIEC 60947-3
Control TypeRotary handle
Handle ColorRed
Network TypeAC · DC
Product NameTeSys VARIO
Product TypeEmergency stop switch disconnector
Base Dimension60 x 60 mm
Product Weight0.25 kg
Fire Resistance960 °C conforming to IEC 60695-2-1
Mounting MethodBy 4 screws for handle
Number of Poles3P
Mounting SupportHandle: door · Switch: door
Breaking Capacity320 A at 400 V (AC-21A) · 320 A at 400 V (AC-22A) · 320 A at 400 V (AC-23A)
Device Short NameVCF
Performance LevelHigh performance
Tightening TorquePower circuit: 2.1 N.m - on screw clamp terminals
Device CompositionSwitch · Handle
Degree of ProtectionIP20 conforming to IEC 60529 · IP65
Protective TreatmentTC
Electrical Durability100000 cycles AC-21 · 30000 cycles DC-1...5
Mechanical Durability100000 cycles
Mechanical RobustnessVibrations 10...150 Hz (1 gn) conforming to IEC 60068-2-6 · Shocks 11 ms (30 Gn) conforming to IEC 60068-2-27
Product CertificationsUL · CCC · GL · CSA · UKCA
IEC Terminal ConnectionPower circuit: screw clamp terminals10 mm² - solid · Power circuit: screw clamp terminals6 mm² - flexible - with cable end
Intermittent Duty Class30
Handle Front Plate ColorYellow
Making Capacity ( I Rms)400 A at 400 V AC-21A · 400 A at 400 V AC-22A · 400 A at 400 V AC-23A
Rotary Handle Padlocking1 to 3 padlocks 4…8 mm
Suitability for IsolationYes
Contact Type and Composition3 NO
Rotary Handle Mounting StyleDirect
[Ie] Rated Operational Current29 A AC-23 Ue: 400 V
IEC Rated Operational Power in W11 kW at 690 V (AC-3) · 15 kW at 690 V (AC-23A) · 11 kW at 400...415 V (AC-3) · 15 kW at 500 V (AC-3) · 18.5 kW at 500 V (AC-23A) · 5.5 kW at 230...240 V (AC-3) · 7.5 kW at 230...240 V (AC-23A) · 15 kW at 400...415 V (AC-23A)
[Ue] IEC Rated Operational Voltage690 V AC 50/60 Hz
Ambient Air Temperature for Operation-20…50 °C
[Uimp] Rated Impulse Withstand Voltage8 kV
Rated Conditional Short Circuit Current10 kA at 400 V - associated fuse 50 A aM · 10 kA at 400 V - associated fuse 50 A gG
[Icw] Rated Short Time Withstand Current480 A at 400 V duration: 1 s
[Icm] Rated Short Circuit Making Capacity1 kA at 400 V at Ipeak
[Ith] Conventional Free Air Thermal Current40 A
[Ithe] Conventional Enclosed Thermal Current32 A
Ratings as published by Schneider (Schneider spec table; se.com; Product title). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
What is the difference between an isolator and an MCB?

An isolator (switch-disconnector) only switches the circuit on and off and does not trip on overload or short circuit, while an MCB provides protection. Isolators are used as main switches in DBs or near equipment for safe maintenance, and must be backed by a suitable MCB, MCCB or fuse.

Can I use an isolator as the main switch in my DB?

Yes, a DP isolator for single-phase or 4P isolator for three-phase is commonly used as the DB incomer, provided protection is given upstream (by the meter-side fuse or MCB) and on each outgoing circuit. Its current rating should be equal to or higher than the upstream protection rating.

Is this isolator safe to switch on load?

Switch-disconnectors to IS/IEC 60947-3 are rated for switching under load according to their utilisation category, such as AC-22 for mixed resistive and inductive loads or AC-23 for motor loads. Check the category on the product before using it to switch motors directly.

2 pole or 4 pole isolator - which one do I need?

Use 2 pole for single-phase supply (phase and neutral) and 4 pole for three-phase supply with neutral, so all live conductors are disconnected during maintenance. A 3 pole isolator is used where no neutral is switched, such as some motor feeders.

Can an isolator be locked off for maintenance?

Many isolators and rotary switch-disconnectors have a padlocking provision in the OFF position so no one can switch them on while work is in progress. Check for the lock-off feature if it is needed for your site's safety procedures.

No reviews yet