🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand DPX³ 250 MCCB · 4P (FP) · 100 A · 70 kA · electronic S2 (LSI) with energy metering and earth leakage module · 420687420687↓ 26% off
BrandLegrand
CategorySwitchgear
Specification4P · 100 A · 70 kA · electronic S2 (LSI) with energy metering and earth leakage module
Brand SKU420687
AvailabilityOn order · 2 to 3 weeks
Delivery8 to 15 business days after dispatch
Legrand· On order, 2 to 3 weeks
Visit the Legrand store

Legrand DPX³ 250 MCCB · 4P (FP) · 100 A · 70 kA · electronic S2 (LSI) with energy metering and earth leakage module · 420687

$1,746.84/pc-26%
$2,360.60
Wholesale · 15+ units
$1,659.49 /pc
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Legrand for you once you place the order.
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$1,746.84 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCCB
FP (4 pole)
100 A
-
-
$6.34 /pc
MCCB
FP (4 pole)
100 A
-
-
$183.84 /pc
MCCB
FP (4 pole)
100 A
-
70 kA
$523.26 /pc
MCCB
FP (4 pole)
100 A
-
70 kA
$727.79 /pc
MCCB
FP (4 pole)
100 A
-
70 kA
$758.62 /pc
MCCB
FP (4 pole)
100 A
-
70 kA
$852.56 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $1,659.49/pc on this product, applied automatically

MCCB electronic + energy metering + e.l.c.bs - DPX³ 250 - Icu 70 kA - 4P - 100 A.

  • Rated Current: 100A
  • No. of Poles: 4P
  • Rated insulation voltage Ui (V): 500
  • Rated operating voltage (50/60Hz) Ue (V): 500
  • Rated impulse withstand current Uimp (kV): 6
As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DPX³ 250 MCCB · 4P (FP) · 100 A · 70 kA · electronic S2 (LSI) with energy metering and earth leakage module · 420687 · 420687
SeriesDPX³
Poles4P (FP)
Rated current100 A
Breaking capacity70 kA
Ultimate breaking capacity (Icu)70 kA
Insulation voltage (Ui)500 V
Impulse withstand (Uimp)6 kV
Warranty18 months from the date of shipment or 12 months from the date of installation
Device typeMiniature circuit breaker (MCB)
Current rating100 A
Reference standardIS/IEC 60898-1
BrandLegrand
Brand SKU420687
ELINE9KGFC4JK7
Sold asPer pc
Ratings as published by Legrand (legrand.co.in; price list; Product title). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet