Schneider TeSys LC1K Power Contactor · 3P · 6 A AC-3 · 1 NO aux · 110 V AC coil · LC1K0610F7LC1K0610F7↓ 40% off1 / 4
BrandSchneider
CategoryIndustrial Control
Specification3P · 6 A AC-3 · 1 NO aux · 110 V AC coil
Brand SKULC1K0610F7
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider TeSys LC1K Power Contactor · 3P · 6 A AC-3 · 1 NO aux · 110 V AC coil · LC1K0610F7

$28.07/pc-40%
$46.76
Wholesale · 15+ units
$26.66 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$28.07 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $26.66/pc on this product, applied automatically

TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides a 110V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider TeSys LC1K Power Contactor · 3P · 6 A AC-3 · 1 NO aux · 110 V AC coil · LC1K0610F7 · LC1K0610F7
Poles3P (TP)
Rated current6 A
Ingress protectionIP2X
Reference standardEN/IEC 60947-4-1
coil voltage110 V AC 50/60 Hz
Net weight0.18 kg
BrandSchneider
Brand SKULC1K0610F7
ELINE9FD9PPCF3
Sold asPer pc
RangeTeSys
Width45 mm
Height58 mm
Motor power kW1.5 kW at 220...230 V AC 50/60 Hz AC-3 · 2.2 kW at 380...415 V AC 50/60 Hz AC-3 · 3 kW at 440/690 V AC 50/60 Hz AC-3 · 1.5 kW at 220...230 V AC 50/60 Hz AC-3e · 2.2 kW at 380...415 V AC 50/60 Hz AC-3e · 3 kW at 440/690 V AC 50/60 Hz AC-3e · 1.5 kW at 220...230 V AC 50/60 Hz AC-4 · 2.2 kW at 380...415 V AC 50/60 Hz AC-4 · 3 kW at 440/690 V AC 50/60 Hz AC-4
Operating time10...20 ms coil de-energisation and NO opening · 10...20 ms coil energisation and NO closing
Coil technologyWithout built-in suppressor module
Heat dissipation1.3 W
Mounting supportPlate · Rail
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Device short nameLC1K
Poles description3P
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 2 · 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm · 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Device applicationControl
Inrush power in VA30 VA (at 20 °C)
Control circuit typeAC at 50/60 Hz
Non overlap distance0.5 mm
Overvoltage categoryIII
Utilisation categoryAC-3 · AC-3e · AC-4
Contactor applicationMotor control
Electrical durability1.3 Mcycles 6 A AC-3 at Ue <= 440 V · 1.3 Mcycles 6 A AC-3e at Ue <= 440 V · 0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Insulation resistance> 10 MOhm for signalling circuit
Mechanical durability10 Mcycles
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC
Associated fuse rating25 A gG at <= 440 V for power circuit · 25 A aM for power circuit · 10 A gG for signalling circuit conforming to IEC 60947 · 10 A gG for signalling circuit conforming to VDE 0660
Maximum operating rate3600 cyc/h
Auxiliary contacts typetype instantaneous 1 NO
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid · Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end · Screw clamp terminals 2 cable(s) 1.5…4 mm²solid · Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947 · 110 A at 380...400 V conforming to IEC 60947 · 110 A at 415 V conforming to IEC 60947 · 110 A at 440 V conforming to IEC 60947 · 80 A at 500 V conforming to IEC 60947 · 70 A at 660...690 V conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 · B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Product or component typeContactor
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947 · 110 A AC for signalling circuit conforming to IEC 60947
Signalling circuit frequency<= 400 Hz
[Uc] control circuit voltage110 V AC 50/60 Hz
Auxiliary contact composition1 NO
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508 · Power circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-5-1 · Signalling circuit: 600 V conforming to UL 508 · Power circuit: 600 V conforming to CSA C22.2 No 14 · Signalling circuit: 600 V conforming to CSA C22.2 No 14
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C)
[Ie] rated operational current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit · 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz · Signalling circuit: <= 690 V AC <= 400 Hz
power pole contact composition3 NO
Hold-in power consumption in VA4.5 VA (at 20 °C)
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit · 85 A 50 °C - 5 s for power circuit · 80 A 50 °C - 10 s for power circuit · 60 A 50 °C - 30 s for power circuit · 45 A 50 °C - 1 min for power circuit · 40 A 50 °C - 3 min for power circuit · 20 A 50 °C - >= 15 min for power circuit · 80 A - 1 s for signalling circuit · 90 A - 500 ms for signalling circuit · 110 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit · 10 A (at 50 °C) for signalling circuit
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.