🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider TeSys LC2K Reversing Contactor · 3P · 12 A AC-3 · 1 NO aux · 24 V AC coil · LC2K1210B7LC2K1210B7↓ 40% off1 / 4
BrandSchneider
CategoryIndustrial Control
Specification3P · 12 A AC-3 · 1 NO aux · 24 V AC coil
Brand SKULC2K1210B7
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider TeSys LC2K Reversing Contactor · 3P · 12 A AC-3 · 1 NO aux · 24 V AC coil · LC2K1210B7

$102.83/pc-40%
$171.39
Wholesale · 15+ units
$97.70 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$102.83 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $97.70/pc on this product, applied automatically

TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V). It provides 24V 50/60Hz AC coils, 2NO built-in auxiliary contacts, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider TeSys LC2K Reversing Contactor · 3P · 12 A AC-3 · 1 NO aux · 24 V AC coil · LC2K1210B7 · LC2K1210B7
Poles3P (TP)
Rated current12 A
Ingress protectionIP20
Reference standardEN/IEC 60947-4-1
coil voltage24 V AC 50/60 Hz
Net weight0.39 kg
BrandSchneider
Brand SKULC2K1210B7
ELINE7D742CPF4
Sold asPer pc
RangeTeSys
StandardsEN/IEC 60947-4-1 · GB/T 14048.4 · UL 60947-4-1 · CSA C22.2 No 60947-4-1 · JIS C8201-4-1
Product nameTeSys K
Motor power kW3 kW at 220...230 V AC 50/60 Hz · 5.5 kW at 380...415 V AC 50/60 Hz · 5.5 kW at 440 V AC 50/60 Hz · 4 kW at 690 V AC 50/60 Hz
Operating time10...20 ms coil energisation and NO closing · 10...20 ms coil de-energisation and NO opening
Heat dissipation1.3 W
Mounting supportPlate · Rail
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Device short nameLC2K
Interlocking typeMechanical
Poles description3P
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 2 · 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
Device applicationControl
Inrush power in VA30 VA (at 20 °C)
Device presentationPreassembled with reversing power busbar
Control circuit typeAC at 50/60 Hz
Non overlap distance0.5 mm
Overvoltage categoryIII
Utilisation categoryAC-3 · AC-3e · AC-4 · AC-1
Contactor applicationResistive load · Motor control
Electrical durability1.3 Mcycles 12 A AC-3 at Ue <= 440 V · 1.3 Mcycles 12 A AC-3e at Ue <= 440 V · 0.3 Mcycles 20 A AC-1 at Ue <= 690 V · 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Mechanical durability5 Mcycles
Associated fuse rating25 A gG at <= 440 V for power circuit · 25 A aM for power circuit · 10 A gG for signalling circuit conforming to IEC 60947 · 10 A gG for signalling circuit conforming to VDE 0660
Maximum operating rate3600 cyc/h
Product certificationsCB Scheme · CCC · UL · CSA · EAC · CE · UKCA
Auxiliary contacts typetype instantaneous 1 NO
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid · Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end · Screw clamp terminals 2 cable(s) 1.5…4 mm²solid · Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Rated breaking capacity110 A at 440 V conforming to IEC 60947 · 80 A at 500 V conforming to IEC 60947 · 70 A at 660...690 V conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 · B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Product or component typeReversing contactor
Irms rated making capacity144 A AC for power circuit conforming to IEC 60947 · 110 A AC for signalling circuit conforming to IEC 60947
Signalling circuit frequency<= 400 Hz
[Uc] control circuit voltage24 V AC 50/60 Hz
Auxiliary contact composition1 NO
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508 · Power circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-5-1 · Signalling circuit: 600 V conforming to UL 508 · Power circuit: 600 V conforming to CSA C22.2 No 14 · Signalling circuit: 600 V conforming to CSA C22.2 No 14
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at <50 °C) · Drop-out: 0.2...0.75 Uc (at <50 °C)
[Ie] rated operational current12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit · 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit · 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
[Ue] rated operational voltagePower circuit: 690 V AC 50/60 Hz · Signalling circuit: <= 690 V AC 50/60 Hz
power pole contact composition3 NO
Hold-in power consumption in VA4.5 VA (at 20 °C)
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit · 105 A 50 °C - 5 s for power circuit · 100 A 50 °C - 10 s for power circuit · 75 A 50 °C - 30 s for power circuit · 55 A 50 °C - 1 min for power circuit · 50 A 50 °C - 3 min for power circuit · 25 A 50 °C - >= 15 min for power circuit · 80 A - 1 s for signalling circuit · 90 A - 500 ms for signalling circuit · 110 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit · 10 A (at 50 °C) for signalling circuit
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet