Schneider Acti9 xID RCCB · 2P · 63 A · 300 mA · Type A-SI (Super Immunised) · A9N16246A9N16246↓ 40% off1 / 2
BrandSchneider
CategorySwitchgear
Specification2P · 63 A · 300 mA · Type A-SI (Super Immunised)
Brand SKUA9N16246
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 xID RCCB · 2P · 63 A · 300 mA · Type A-SI (Super Immunised) · A9N16246

Rating: 63 A
Poles: 2P
Sensitivity: 300 mA
$174.01/pc-40%
$290.04
Wholesale · 15+ units
$165.32 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$174.01 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB · Type A
2P / 1P+N (single phase)
63 A
n/a
300 mA
$174.01 /pc
Viewing above ↑
RCCB
2P / 1P+N (single phase)
63 A
n/a
300 mA
$60.47 /pc
RCCB
2P / 1P+N (single phase)
63 A
n/a
300 mA
$83.61 /pc
RCCB · Type A
2P / 1P+N (single phase)
63 A
n/a
300 mA
$98.41 /pc
RCCB
2P / 1P+N (single phase)
63 A
n/a
300 mA
$131.40 /pc
RCCB · Type A
2P / 1P+N (single phase)
63 A
n/a
300 mA
$174.53 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $165.32/pc on this product, applied automatically

This product is a Acti9 xID biconnect residual current circuit breaker (RCCB). It is a 2P circuit breaker with 63A In rated current, a sensitivity of 300mA with a A-SI type protection class. This product protects against electrical shock by indirect contact and fire hazards. The connection is made downstream by biconnect comb busbar or upstream/downstream by tunnel terminals. It has increased immunity from electrical interference reducing the risk of nuisance tripping. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is up to 630A . The mechanical endurance is going up to 4000 cycles and electrical endurance going up to 4000 cycles. The Ue operational voltage is 230VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 81mm x (D) 75mm. The weight is 210g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 40°C. The storage

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 xID RCCB · 2P · 63 A · 300 mA · Type A-SI (Super Immunised) · A9N16246 · A9N16246
Poles2P (DP)
Rated current63 A
Sensitivity (IΔn)300 mA
Ingress protectionIP20
Reference standardIEC 61008-2-1
Net weight0.21 kg
ColourWhite
Device typeResidual current circuit breaker (RCCB)
Current rating63 A
Sensitivity300 mA
BrandSchneider
Brand SKUA9N16246
ELINE6R4HM39DJ
Sold asPer pc
Depth75 mm
RangeActi9
Width36 mm
Height81 mm
StandardsIEC 61008-2-1 · EN 61008-2-1 · EN/IEC 61008-1
9 mm pitches4
Control typeToggle
Network typeAC
Product nameActi9 xID
Mounting modeClip-on
Tropicalisation2 conforming to IEC 60068-1
Connection pitch18 mm between phases
Local signallingON, OFF, fault trip
Mounting supportDIN rail
Neutral positionLeft
Pollution degree2
Device short namexID
Network frequency50 Hz
Poles description2P
Relative humidity95 % at 55 °C
Tightening torque3.5 N.m top or bottom
[In] rated current63 A
Electrical durability4000 cycles
Mechanical durability4000 cycles
Wire stripping length14 mm for top or bottom connection
Product certificationsISI
Connections - terminalsTunnel type terminals (top or bottom) 1…35 mm² rigid · Tunnel type terminals (top or bottom) 1…25 mm² flexible
IP degree of protectionIP20
Earth-leakage sensitivity300 mA
Product or component typeResidual current circuit breaker (RCCB)
Suitability for isolationYes
Contact position indicatorYes
Locking options descriptionPadlocking device
[Ui] rated insulation voltage500 V AC 50 Hz
Earth-leakage protection classType A-SI (Super Immunised)
[Ue] rated operational voltage230...240 V AC 50 Hz
Rated breaking and making capacity630 A conforming to EN/IEC 61008-1
Ambient air temperature for storage-40…85 °C
Earth-leakage protection time delaySelective
Ambient air temperature for operation-5…40 °C
[Uimp] rated impulse withstand voltage6 kV
Comb busbar and distribution block compatibilityDownside: biconnect
Ratings as published by Schneider (se.com; Schneider spec table). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
THIS UNIT
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

What sensitivity is this RCCB?

This RCCB trips at a residual (leakage) current of 300 mA. 30mA is the standard for personal shock protection, while 100mA and 300mA are used for equipment and fire protection.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

Is this a 2 pole or 4 pole RCCB?

The pole configuration of this RCCB is 2P. 2 pole is used on single-phase supply and 4 pole on three-phase supply with neutral, and the neutral of every protected circuit must pass through the same RCCB.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.

No reviews yet