Lauritz Knudsen AU Solar DC SPD · Type 1+2 · 3P (TP) · Imax 50 kA · Ucpv 1360 V · AUSP123P50-1360AUSP123P50-1360↓ 27% off
BrandLauritz Knudsen
CategorySwitchgear
SpecificationSolar DC SPD Type 1+2 · 3P · Imax 50 kA · Iimp 12.5 kA · Ucpv 1360 V DC · 5 modules · 800 V solar application
Brand SKUAUSP123P50-1360
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen AU Solar DC SPD · Type 1+2 · 3P (TP) · Imax 50 kA · Ucpv 1360 V · AUSP123P50-1360

$577.10/pc-27%
$788.82
Wholesale · 15+ units
$548.23 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$577.10 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $548.23/pc on this product, applied automatically

AU surge protection devices from Lauritz Knudsen, Type 2 and Type 1+2, for 440 V AC and 800 V solar DC applications, with pluggable cartridges.

  • Conforms to IEC 61643-11
  • Available in Type 2 and Type 1+2
  • Type 2: protection against indirect lightning and switching surges, Imax up to 70 kA
  • Type 1+2: protection against direct and indirect lightning, Imax up to 100 kA
  • Pluggable cartridge for each pole
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen AU Solar DC SPD · Type 1+2 · 3P (TP) · Imax 50 kA · Ucpv 1360 V · AUSP123P50-1360 · AUSP123P50-1360
Device typeSurge protection device (SPD)
SeriesAU
Poles3P (DC+, DC-, earth)
SPD typeType 1+2
Max continuous DC voltage (Ucpv)1360 V DC
Max discharge current (Imax)50 kA
Impulse current (Iimp)12.5 kA
Width5 modules
Reference standardIEC 61643-31
Breaking capacity50 kA
BrandLauritz Knudsen
Brand SKUAUSP123P50-1360
ELINE66PD3G63C
Sold asPer pc
Ratings as published by Lauritz Knudsen (Lauritz Knudsen price list Aug 2026). Verify critical parameters against the datasheet before specifying.
Other Lauritz Knudsen ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which type of SPD should I use for my home - Type 1 or Type 2?

For most homes and apartments, a Type 2 SPD in the main DB is the standard choice. Type 1 or combined Type 1+2 is used at the service entrance of independent houses in lightning-prone areas or buildings with external lightning protection (SPDs are covered by IS 16463 (Part 11), identical to IEC 61643-11).

Does an SPD need earthing?

Yes. An SPD diverts surge energy to earth, so it works only with a proper, low-resistance earth connection kept as short as possible. Without good earthing it gives little or no protection.

Will an SPD protect against high voltage from neutral failure?

No. SPDs are designed for short transient surges from lightning and switching, not sustained overvoltage such as from a broken neutral or poor supply. For that, use a voltage protection relay, an over/under voltage protector or stabilisers for sensitive equipment.

How do I know when the SPD needs replacing?

Most SPDs have an indicator window that turns from green to red when the protective element has reached end of life. Pluggable SPDs allow replacing only the cartridge; check the indicator periodically and after major thunderstorms.

Does an SPD need an MCB or fuse before it?

Yes, an SPD should have backup protection (MCB or fuse) as specified by the manufacturer, so a failed SPD can be safely disconnected without tripping the whole installation. The backup rating is usually listed in the SPD datasheet.

What do Imax, In and Up mean on an SPD?

Imax is the maximum surge current it can discharge once, In is the nominal current it can handle repeatedly, and Up is the voltage protection level (the let-through voltage), where lower is better. For 230 V homes, a Type 2 SPD with Imax around 40kA and a maximum continuous operating voltage (Uc) of 275 V or more is commonly used.

No reviews yet