Schneider ComPacT NSX100H MCCB · 3P · 40 A · 100 kA · MicroLogic 2.2 · C10H32D040C10H32D040↓ 40% off1 / 6
BrandSchneider
CategorySwitchgear
Specification3P · 40 A · 100 kA · MicroLogic 2.2
Brand SKUC10H32D040
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider ComPacT NSX100H MCCB · 3P · 40 A · 100 kA · MicroLogic 2.2 · C10H32D040

Rating: 40 A
Poles: 3P
$630.15/pc-40%
$1,050.24
Wholesale · 15+ units
$598.64 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$630.15 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $598.64/pc on this product, applied automatically

This ComPacT NSX100H is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds an electronic MicroLogic 2.2 trip unit, with 40A rating. MicroLogic 2.2 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX100H is part of Schneider Electric EcoStruxure Power architecture.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider ComPacT NSX100H MCCB · 3P · 40 A · 100 kA · MicroLogic 2.2 · C10H32D040 · C10H32D040
Poles3P (TP)
Rated current40 A
Breaking capacity100 kA
Ingress protectionIP40
Reference standardEN/IEC 60947-2
Net weight2.05 kg
Device typeMiniature circuit breaker (MCB)
Current rating40 A
BrandSchneider
Brand SKUC10H32D040
ELINE63GF4GJHR
Sold asPer pc
RangeComPacT
Control typeToggle
Network typeAC
Product nameComPacT NSX
Thermal memory20 minutes before and after tripping
Trip unit nameMicroLogic 2.2
Protection typeL : for overload protection (long time) · So : for short time short-circuit protection with fixed delay · I : for instantaneous short-circuit protection
Connection pitch35 mm
Mounting supportBackplate
Trip unit rating40 A at 40 °C
Device short nameNSX100H
Mounting positionHorizontal and vertical · Flat on the back
Network frequency50/60 Hz
Poles description3P
Upside connectionFront
Device applicationDistribution
[In] rated current40 A at 40 °C
Downside connectionFront
Trip unit technologyElectronic
Utilisation categoryCategory A
Electrical durability50000 cycles at 440 V In/2 · 30000 cycles at 440 V In · 20000 cycles at 690 V In/2 · 10000 cycles at 690 V In
Mechanical durability50000 cycles
Breaking capacity codeH 70 kA 415 V AC
Earth-leakage protectionWithout
Product or component typeCircuit breaker
Suitability for isolationYes conforming to EN/IEC 60947-2
Power dissipation per pole1.3 W
Protected poles description3D
Circuit breaker mounting modeFixed
[Ui] rated insulation voltage800 V AC 50/60 Hz
Trip unit protection functionsLSoI
[Ue] rated operational voltage690 V AC 50/60 Hz
Zone selective interlocking ZSIWithout
[Ics] rated service breaking capacity100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 · 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 · 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 · 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[tr] long-time delay adjustment range400 s at 1.5 x Ir · 16 s at 6 x Ir · 11 s at 7.2 x Ir
[Uimp] rated impulse withstand voltage8 kV
Long-time protection delay adjustment type trFixed
Short-time protection delay adjustment type tsdFixed
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Ir] long-time protection pick-up adjustment range18...40 A
Instantaneous protection pick-up adjustment type IiFixed
[Isd] Short-time protection pick-up adjustment range1.5...10 x Ir
[Ii] instantaneous protection pick-up adjustment range600 A
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

What breaking capacity does this MCCB have?

This MCCB has a breaking capacity of 100 kA. It must be higher than the prospective short-circuit current at the point of installation, which depends mainly on the transformer size and cable length from it.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet