🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider TeSys GVAU Voltage Release · TeSys GV2 & GV3 · undervoltage trip · 220-240 V AC 50 Hz · GVAU225GVAU225↓ 40% off1 / 2
BrandSchneider
CategoryIndustrial Control
SpecificationTeSys GV2 & GV3 · undervoltage trip · 220...240 V AC 50 Hz
Brand SKUGVAU225
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider TeSys GVAU Voltage Release · TeSys GV2 & GV3 · undervoltage trip · 220-240 V AC 50 Hz · GVAU225

$74.05/pc-40%
$123.43
Wholesale · 15+ units
$70.35 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$74.05 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $70.35/pc on this product, applied automatically

TeSys GV electrical trip, MN undervoltage release, 220-240V AC 50Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage is applied in the range 0.85-1.1 Uc. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider TeSys GVAU Voltage Release · TeSys GV2 & GV3 · undervoltage trip · 220-240 V AC 50 Hz · GVAU225 · GVAU225
coil voltage220...240 V AC 50 Hz
ColourDark grey
Net weight0.105 kg
BrandSchneider
Brand SKUGVAU225
ELINE63DF2PFG2
Sold asPer pc
Depth66 mm
RangeTeSys · TeSys Deca
Width18 mm
Height89 mm
On-load factor100 %
Operating time10...15 ms conforming to IEC 60947-1
Quantity per setSet of 10
Device short nameGVAU
Inrush power in W8 W
Tightening torque< 1.4 N.m on screw clamp terminals
Inrush power in VA12 VA AC
Range compatibilityTeSys GV2ME · TeSys GV2LE · TeSys GV2L · TeSys GV2P · TeSys GV3L · TeSys GV3P · TeSys Deca
Mechanical durability10000 cycles with GV3P and GV3L · 30000 cycles with GV2ME and GV2P
Connections - terminalsScrew clamp terminals 1 cable(s) 1…2.5 mm²solid · Screw clamp terminals 2 cable(s) 1…2.5 mm²solid · Screw clamp terminals 1 cable(s) 0.75…2.5 mm²flexible without cable end · Screw clamp terminals 2 cable(s) 0.75…2.5 mm²flexible without cable end · Screw clamp terminals 1 cable(s) 0.75…1.5 mm²flexible with cable end · Screw clamp terminals 2 cable(s) 0.75…1.5 mm²flexible with cable end
Product or component typeUndervoltage release
Threshold tripping voltage0.7...0.35 Un
[Uc] control circuit voltage220...240 V AC 50 Hz
[Ui] rated insulation voltage690 V AC conforming to IEC 60947-1 · 600 V AC conforming to UL 60947-4-1 · 600 V AC conforming to CSA C22.2 No 60947-4-1
Control circuit voltage limits0.85...1.1 Un
Hold-in power consumption in W1.1 W
Hold-in power consumption in VA3.5 VA AC
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
What is the difference between MPCB and MCB for a motor?

An MPCB has an adjustable overload setting matched to the motor's current and a magnetic trip set to handle motor starting current, plus phase loss sensitivity. An MCB has fixed overload settings meant for cables, so it does not protect a motor as precisely (MPCBs are covered by IS/IEC 60947-2 and 60947-4-1).

Can an MPCB replace an overload relay and fuses?

Yes, an MPCB gives short-circuit and overload protection plus isolation in one device, so with a contactor it forms a compact DOL starter without a separate overload relay or fuses. Check the manufacturer's coordination table for the right contactor pairing.

Can I start and stop the motor directly with the MPCB?

Yes, an MPCB can be used as a manual motor starter for occasional on/off switching. For frequent starts, remote control or float/pressure switch operation, pair it with a contactor.

Which accessories are available for an MPCB?

Common accessories include auxiliary contacts, trip-indication contacts, undervoltage and shunt releases, enclosures for wall mounting and connection links to contactors. These are usually specific to the MPCB range.

My MPCB trips when the motor starts - what should I check?

Check that the dial is set to the motor's full-load current, that all three phases are present and balanced, and that the pump or load is not jammed. If the motor current is near the top of the range, the next range up may be needed; consult an electrician before increasing settings.

No reviews yet