Lauritz Knudsen dsine DN4-1250N MCCB · 3P (TP) · 320-800 A · 50 kA · microprocessor release MTX2.0 · CM96021OOOOAGCM96021OOOOAG↓ 27% off
BrandLauritz Knudsen
CategorySwitchgear
Specificationdsine DN4-1250N MCCB · 3P (TP) · 320-800 A · Icu 50 kA at 415 V · microprocessor release MTX2.0 (with ground-fault protection and metering display)
Brand SKUCM96021OOOOAG
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen dsine DN4-1250N MCCB · 3P (TP) · 320-800 A · 50 kA · microprocessor release MTX2.0 · CM96021OOOOAG

$2,021.79/pc-27%
$2,763.51
Wholesale · 15+ units
$1,920.68 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$2,021.79 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $1,920.68/pc on this product, applied automatically

dsine DN MCCBs from Lauritz Knudsen with the MTX2.0 microprocessor release: ground-fault and neutral protection plus a panel-mounted metering display.

  • Conforms to IS/IEC 60947-2
  • 40 A to 1250 A, 3P and 4P
  • 36 kA, 50 kA, 70 kA and 100 kA breaking capacities
  • Ics = 100% Icu
  • Adjustable overload 0.4 to 1.0 x In and short-circuit 1.5 to 8 x Ir
  • Inbuilt instantaneous protection
  • Inbuilt ground fault protection 20% to 50% of In
  • Adjustable neutral overload protection 50% to 150% of Ir
  • Switchable thermal memory, variable trip class, front LED
  • Panel-mounted display for current metering and trip record
Ordering note
Phase barriers are supplied with the MCCB.
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen dsine DN4-1250N MCCB · 3P (TP) · 320-800 A · 50 kA · microprocessor release MTX2.0 · CM96021OOOOAG · CM96021OOOOAG
Device typeMoulded case circuit breaker (MCCB)
Seriesdsine DN
FrameDN4-1250N
Poles3P (TP)
Rated current800 A
Breaking capacity50 kA
Rated voltage415 V AC
Ultimate breaking capacity (Icu)50 kA at 415 V AC
Service breaking capacity (Ics)50 kA (Ics = 100% Icu)
Setting range320-800 A
Releasemicroprocessor release MTX2.0 (with ground-fault protection and metering display)
Reference standardIS/IEC 60947-2
Current rating800 A
BrandLauritz Knudsen
Brand SKUCM96021OOOOAG
ELINE4HH2G6DGH
Sold asPer pc
Ratings as published by Lauritz Knudsen (Lauritz Knudsen price list Aug 2026; Product title). Verify critical parameters against the datasheet before specifying.
Other Lauritz Knudsen ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet