🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider ComPacT MX Voltage Release · MX shunt trip release · Compact NSX · PowerPact Multistandard · 220-240 V AC 50/60 Hz · LV429387LV429387↓ 40% off1 / 3
BrandSchneider
CategorySwitchgear
SpecificationMX shunt trip release · Compact NSX · PowerPact Multistandard · EasyPact CVS · rated voltage 220 to 240 VAC 50/60 Hz
Brand SKULV429387
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider ComPacT MX Voltage Release · MX shunt trip release · Compact NSX · PowerPact Multistandard · 220-240 V AC 50/60 Hz · LV429387

$48.72/pc-40%
$81.20
Wholesale · 15+ units
$46.28 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$48.72 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $46.28/pc on this product, applied automatically

This is a MX shunt trip release for Compact NSX, PowerPact Multistandard and EasyPact CVS circuit breakers. Its rated voltage is 220 to 240 VAC 50/60 Hz, or 208 to 277 VAC 60 Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage Un rises above 70% of its rated voltage Un. It complies with IEC 60947-2 standard. This shunt trip is a UL Listed/CSA Certified circuit breaker accessory. Compact NSX, PowerPact Multistandard and EasyPact CVS can be equipped with either 1 MX or 1 MN auxiliary.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider ComPacT MX Voltage Release · MX shunt trip release · Compact NSX · PowerPact Multistandard · 220-240 V AC 50/60 Hz · LV429387 · LV429387
coil voltage220...240 V AC 50/60 Hz
Device typeMiniature circuit breaker (MCB)
Reference standardIS/IEC 60898-1
BrandSchneider
Brand SKULV429387
ELINE4C643J9R6
Sold asPer pc
RangeComPacT
Response time50 ms
Impulse duration>= 20 ms
Range of productComPact NSX100...250 · ComPacT NSX100...250 · ComPact NSX400...630 · ComPacT NSX400...630 · ComPact NSX100...250 DC · ComPacT NSX100...250 DC · ComPact NSX100...250 DC PV · ComPacT NSX100...250 DC PV · ComPact NSX400...630 DC · ComPacT NSX400...630 DC · ComPact NSX400...630 DC PV · ComPacT NSX400...630 DC PV
Device short nameMX
Device applicationControl
Control signal typeImpulse · Maintained
Operating threshold0.7...1.1 x Un opening
Range compatibilityComPacT ComPacT NSX · ComPacT ComPacT NSX DC · ComPact ComPact NSX · ComPact ComPact NSX DC · EasyPact EasyPact CVS · PowerPact PowerPact Multistandard
Supply inrush power10 VA
Voltage release typeOpening coil · Shunt trip release
Wire stripping length7 mm
Product or component typeVoltage release
[Uc] control circuit voltage220...240 V AC 50/60 Hz · 208...277 V AC 60 Hz
Auxiliary connection terminalSpring 0.5…1.5 mm² (20 AWG...16 AWG)
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
No reviews yet