Schneider ComPacT NSX100B MCCB · 4P · 16 A · 40 kA · TM-D · C10B6TM016C10B6TM016↓ 40% off1 / 6
BrandSchneider
CategorySwitchgear
Specification4P · 16 A · 40 kA · TM-D
Brand SKUC10B6TM016
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider ComPacT NSX100B MCCB · 4P · 16 A · 40 kA · TM-D · C10B6TM016

Rating: 16 A
Poles: 4P
$308.24/pc-40%
$513.73
Wholesale · 15+ units
$292.82 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$308.24 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $292.82/pc on this product, applied automatically

This ComPacT NSX100B is a complete 4P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 16A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX100B is part of Schneider Electric EcoStruxure Power architecture.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider ComPacT NSX100B MCCB · 4P · 16 A · 40 kA · TM-D · C10B6TM016 · C10B6TM016
Poles4P (FP)
Rated current16 A
Breaking capacity40 kA
Ingress protectionIP40
Reference standardEN/IEC 60947-2
Net weight2.4 kg
Device typeMiniature circuit breaker (MCB)
Current rating16 A
BrandSchneider
Brand SKUC10B6TM016
ELINE42M32HKGR
Sold asPer pc
RangeComPacT
Width (W)140 mm
Height (H)161 mm
Control typeToggle
Network typeAC
Product nameComPacT NSX
Trip unit nameTM-D
Number of slots5 slot(s)
Protection typeL : for overload protection (thermal) · I : for short-circuit protection (magnetic)
Connection pitch35 mm
Mounting supportBackplate
Neutral positionLeft
Trip unit rating16 A at 40 °C
Device short nameNSX100B
Mounting positionHorizontal and vertical · Flat on the back
Network frequency50/60 Hz
Poles description4P
Upside connectionFront
Device applicationDistribution
[In] rated current16 A at 40 °C
Downside connectionFront
Trip unit technologyThermal-magnetic
Utilisation categoryCategory A
Electrical durability50000 cycles at 440 V In/2 · 30000 cycles at 440 V In · 20000 cycles at 690 V In/2 · 10000 cycles at 690 V In
Mechanical durability50000 cycles
Breaking capacity codeB 25 kA 415 V AC
Earth-leakage protectionWithout
Product or component typeCircuit breaker
Suitability for isolationYes conforming to EN/IEC 60947-2
Neutral protection settingNo protection (3D)
Power dissipation per pole2.92 W
Protected poles description3D
Circuit breaker mounting modeFixed
[Ui] rated insulation voltage800 V AC 50/60 Hz
Trip unit protection functionsLI
[Ue] rated operational voltage690 V AC 50/60 Hz
[Ics] rated service breaking capacity40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 · 7 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
[tr] long-time delay adjustment range120…400 s at 1.5 x In · 15 s at 6 x Ir
[Uimp] rated impulse withstand voltage8 kV
Long-time protection delay adjustment type trFixed
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range190 A
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

What breaking capacity does this MCCB have?

This MCCB has a breaking capacity of 40 kA. It must be higher than the prospective short-circuit current at the point of installation, which depends mainly on the transformer size and cable length from it.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.