Schneider PowerLogic PM3250 Power Meter · 1P/3P · 5 A · Class 0.5S active energy · METSEPM3250METSEPM3250↓ 40% off
BrandSchneider
CategoryIndustrial Control
Specification1P/3P · 5 A · Class 0.5S active energy· Class 1 active energy· Class 2 reactive energy· Class C · Modbus at 9.6...38.4 kbauds
Brand SKUMETSEPM3250
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider PowerLogic PM3250 Power Meter · 1P/3P · 5 A · Class 0.5S active energy · METSEPM3250

$270.56/pc-40%
$450.95
Wholesale · 15+ units
$257.04 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$270.56 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $257.04/pc on this product, applied automatically

PM3250 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter offers event recording with up to 5 alarms. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider PowerLogic PM3250 Power Meter · 1P/3P · 5 A · Class 0.5S active energy · METSEPM3250 · METSEPM3250
Rated current5 A
Ingress protectionIP40 front panel:· IP20 body:
Reference standardBS EN 61557-12
Net weight0.26 kg
BrandSchneider
Brand SKUMETSEPM3250
ELINE423F7736F
Sold asPer pc
Depth70 mm
RangePowerLogic
Width90 mm
Height95 mm
StandardsBS EN 61557-12 · IEC 61557-12 · EN 61557-12 · BS EN 61326-1 · IEC 61326-1 · EN 61326-1 · BS EN 62052-11 · IEC 62052-11 · EN 62052-11 · BS EN 62053-21 · IEC 62053-21 · EN 62053-21 · BS EN 62053-22 · IEC 62053-22 · EN 62052-22 · BS EN 62053-23 · IEC 62053-23 · EN 62052-23 · BS EN 61010-1 · EN 61010-1 · IEC 61010-1 · UL 61010-1 · BS EN 61010-2-30 · IEC 61010-2-30 · EN 61010-2-30 · UL 61010-2-30 · ANS
Display typeBacklit LCD
Product namePowerLogic PM3000
Mounting modeClip-on
Sampling rate32 samples/cycle
Accuracy classClass 0.5S active energy conforming to IEC 62053-22 · Class 1 active energy conforming to IEC 62053-21 · Class 2 reactive energy conforming to IEC 62053-23 · Class C active energy conforming to EN 50470-3
Data recordingTime stamping · Min/max of instantaneous values · 5 alarms
Market segmentBuildings small building cost management: billing: sub feeder · Buildings medium building cost management: billing: sub feeder · Buildings large building cost management: billing: sub feeder · Buildings multi-site cost management: billing: sub feeder · Data center cost management: billing: sub feeder · Healthcare cost management: billing: sub feeder · Industry cost management: billing: sub feeder
supply voltage100...277 V AC 45...65 Hz · 173...480 V AC 45...65 Hz · 100...300 V DC
type of network1P + N · 3P · 3P + N
Mounting supportDIN rail
Number of inputs0
Pollution degree2
Device short namePM3250
Network frequency60 Hz · 50 Hz
Number of outputs0
Relative humidity5…95 % at 50 °C
Compatibility codePM3250
Device applicationMulti-tariff · Power monitoring · Sub billing
Display resolution128 x 96 pixels
Operating altitude< 3000 m
[In] rated current5 A · 1 A
Analogue input typeCurrent 0...5 A · Current 0...1 A
Measurement current0.02…1.2 A · 0.05…6 A
Measurement voltage50…330 V AC 45...65 Hz direct · 50…330 V AC 45...65 Hz phase to neutral · 80…570 V AC 45...65 Hz direct · 80…570 V AC 45...65 Hz phase to phase · 570…999000 V AC 45...65 Hz with external VT
Type of measurementActive and reactive power · Apparent power · Current · Voltage · Energy · Power factor · Frequency · Total current harmonic distortion THD (I) · Total voltage harmonic distortion THD (U)
Measurement accuracyCurrent 0.3 % 0.5...6 A · Current 0.5 % 0.1...1.2 A · Voltage 0.3 % 50...330 V · Voltage 0.3 % 80...570 V
Overvoltage categoryIII
Information displayedTariff (4)
Power quality analysisup to the 15th harmonic
Product certificationsCE conforming to IEC 61010-1 (safety) · CE conforming to EN 61557-12 (power monitor) · CE conforming to EN/IEC 61326-1 (EMC) · UKCA conforming to BS EN 61010-1 (safety) · UKCA conforming to BS EN 61557-12 (power monitor) · UKCA conforming to BS EN 61326-1 (EMC) · CULus conforming to EN 61010-1 (safety) · CULus conforming to UL 61010-1 (safety) · EAC (sub-meter) · RCM
IP degree of protectionIP40 front panel: conforming to IEC 60529 · IP20 body: conforming to IEC 60529
Power consumption in VA5 VA
Product or component typePower meter
Communication port supportRS485
Communication port protocolModbus at 9.6...38.4 kbauds
Frequency measurement range45…65 Hz
Electromagnetic compatibilityElectrostatic discharge level 4 conforming to IEC 61000-4-2 · Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 · Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 · Surge immunity test level 4 conforming to IEC 61000-4-5 · Conducted RF disturbances level 3 conforming to IEC 61000-4-6 · Magnetic field at power frequency - test level: 0.5 m
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…70 °C
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.