🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider Acti9 C60H-DC MCB · 1P · 0.5 A · C curve · 10 kA · A9N61500A9N61500↓ 40% off
BrandSchneider
CategorySwitchgear
Specification1P · 0.5 A · C curve · 10 kA
Brand SKUA9N61500
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 C60H-DC MCB · 1P · 0.5 A · C curve · 10 kA · A9N61500

Rating: 0.5 A
Poles: 1P
$24.88/pc-40%
$41.46
Wholesale · 15+ units
$23.64 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$24.88 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB · DC
SP
0.5 A
C
10 kA
$24.88 /pc
Viewing above ↑
MCB · DC
SP
0.5 A
C
-
$11.85 /pc
MCB · DC
SP
0.5 A
-
-
$13.51 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $23.64/pc on this product, applied automatically

This Acti9 C60H-DC is a low voltage direct current miniature circuit breaker (MCB). It has 1P, rated current 0.5A and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 220VDC conforming to EN 60947-2 standard and 10kA at 220VDC conforming to EN 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. It offers VisiTrip for safety during maintenance and VisiSafe to reduce intervention time. The Acti9 C60H-DC is used in direct current circuit (industrial control and automation, transport, renewable energy). This device is dedicated to industrial control, automations, transport and renewable energy applications. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 250VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The pr

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 C60H-DC MCB · 1P · 0.5 A · C curve · 10 kA · A9N61500 · A9N61500
Poles1P (SP)
Rated current0.5 A
Trip curveC curve
Breaking capacity10 kA
Reference standardEN 60947-2
Net weight0.128 kg
ColourWhite
Device typeMiniature circuit breaker (MCB)
Current rating5 A
BrandSchneider
Brand SKUA9N61500
ELINE3C9C6R7K9
Sold asPer pc
RangeActi9
StandardsEN 60947-2 · IEC 60947-2
Curve codeC
9 mm pitches2
Control typeToggle
Network typeDC
Product nameActi9 C60H-DC
Mounting modeFixed
Tropicalisation2 conforming to IEC 60068-2
Local signallingON/OFF indication
Mounting support35 mm symmetrical DIN rail
Pollution degree3 conforming to EN 60947-2 · 3 conforming to IEC 60947-2
Device short nameC60H-DC
Network frequency50/60 Hz
Poles description1P
Tightening torquePower circuit: 2.5 N.m top or bottom
Device applicationDistribution
Operating altitude2000 m
[In] rated current0.5 A at 25 °C
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Utilisation categoryCategory A conforming to EN 60947-2 · Category A conforming to IEC 60947-2
Electrical durability3000 cycles L/R = 2 ms
Mechanical durability20000 cycles
Earth-leakage protectionWithout
Provision for padlockingPadlockable
Number of protected poles1
Product or component typeMiniature circuit-breaker
Suitability for isolationYes conforming to IEC 60947-2 · Yes conforming to EN 60947-2
Contact position indicatorYes
Locking options descriptionIn position O
[Ui] rated insulation voltage500 V DC conforming to IEC 60947-2 · 500 V DC conforming to EN 60947-2
[Ue] rated operational voltage250 V DC
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…70 °C
[Ics] rated service breaking capacity15 kA 75 % conforming to EN 60947-2 - 110 V DC · 15 kA 75 % conforming to IEC 60947-2 - 110 V DC · 4.5 kA 75 % conforming to EN 60947-2 - 250 V DC · 4.5 kA 75 % conforming to IEC 60947-2 - 250 V DC · 7.5 kA 75 % conforming to EN 60947-2 - 220 V DC · 7.5 kA 75 % conforming to IEC 60947-2 - 220 V DC
[Uimp] rated impulse withstand voltage6 kV conforming to EN 60947-2 · 6 kV conforming to IEC 60947-2
Comb busbar and distribution block compatibilityTop or bottom: standard
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

What curve is this MCB?

The tripping curve of this MCB is C curve. C is the general-purpose choice for mixed household loads, B suits lighting and resistive circuits, and D is for equipment with heavy inrush current.

What current is this MCB rated for and what wire should I use with it?

This MCB is rated 0.5 A. As a rough guide for copper wiring in Indian homes, 6-10A usually goes with 1.5 sq mm lighting circuits, 16A with 2.5 sq mm socket circuits and 20-32A with 4-6 sq mm, but cable length and installation method matter, so have a licensed electrician confirm.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet