🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider Zelio Logic Smart Relay · compact smart relay Zelio Logic · 20 I O · 12 V DC · clock · SR2B201JDSR2B201JD↓ 40% off1 / 5
BrandSchneider
CategoryIndustrial Control
Specificationcompact smart relay Zelio Logic · 20 I O · 12 VDC · clock · display
Brand SKUSR2B201JD
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Zelio Logic Smart Relay · compact smart relay Zelio Logic · 20 I O · 12 V DC · clock · SR2B201JD

$324.80/pc-40%
$541.34
Wholesale · 15+ units
$308.55 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$324.80 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $308.55/pc on this product, applied automatically

This product is part of Smart Relay - Zelio Logic SR2/SR3, an offer of simple automation systems from 10 to 40 I/Os. This Zelio Logic compact smart relay features 20 I/Os, local display, 0 to 240 with ladder and 0 to 500 with FBD programming control scheme lines. It is a module with rated supply voltage of 12V DC and cycle time of 6ms to 90ms. It offers 12 resistive discrete inputs with voltage of 12V DC, 6 analogue input ranges from 0V to 10V, 0V to 12V and 8 relay outputs. It is an IP20 and IP40 rated product. It weighs 0.38kg. The main application of this module is industry and building/service sector. This product is certified by C-Tick, GL, UL, CSA and GOST. It meets EN/IEC 60068-2-6 Fc and EN/IEC 61000-4-11 standards. Easy to use, Zelio Logic provides a real alternative solutions based on cabled logic or specific cards.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Zelio Logic Smart Relay · compact smart relay Zelio Logic · 20 I O · 12 V DC · clock · SR2B201JD · SR2B201JD
Ingress protectionIP20 (terminal block)· IP40 (front panel)
Reference standardIEC 60068-2-6 Fc
Net weight0.38 kg
BrandSchneider
Brand SKUSR2B201JD
ELINE394HJ62GM
Sold asPer pc
ClockWith
ChecksProgram memory on each power up
LSB value39 mV for analogue input circuit
Cycle time6…90 ms
Backup time10 years at 25 °C
Clock drift12 min/year at 0…55 °C · 6 s/month at 25 °C
Local displayWith
Response time10 ms (from state 0 to state 1) for relay output · 5 ms (from state 1 to state 0) for relay output
Conversion timeSmart relay cycle time for analogue input circuit
Input impedance14 kOhm for IB...IG used as analogue input circuit · 14 kOhm for IB...IG used as discrete input circuit · 2.7 kOhm for I1...IA and IH...IR discrete input circuit
Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
Conversion error+/- 5 % at 25 °C for analogue input circuit · +/- 6.2 % at 55 °C for analogue input circuit
Range of productZelio Logic
Number of outputs8 relay
Counting frequency1 kHz for discrete input
Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
Analogue input typeCommon mode
Discrete input typeResistive
Input compatibility3-wire proximity sensors PNP for discrete input
Analogue input range0...10 V · 0...12 V
Operating rate in Hz0.1 Hz (at Ie) for relay output · 10 Hz (no load) for relay output
Analogue input number6
Discrete input number12 conforming to IEC 61131-2 Type 1
Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to IEC 60947-5-1 · AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to IEC 60947-5-1 · DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to IEC 60947-5-1 · DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to IEC 60947-5-1
Mechanical durability10000000 cycles for relay output
Output voltage limits24...250 V AC (relay output) · 5...30 V DC (relay output)
Supply voltage limits10.4…14.4 V
Discrete input current4 mA
Discrete input voltage12 V DC
Maximum supply current200 mA (without extension)
Output thermal current8 A for all 8 outputs for relay output
Power dissipation in W2.5 W without extension
Switching capacity in mA>= 10 mA at 12 V (relay output)
Analogue input resolution8 bits at maximum voltage
Product or component typeCompact smart relay
[Us] rated supply voltage12 V DC
Current state 0 guaranteed<= 0.9 mA (I1...IA and IH...IR discrete input circuit) · <= 0.9 mA (IB...IG used as discrete input circuit)
Current state 1 guaranteed>= 2 mA (I1...IA and IH...IR discrete input circuit) · >= 0.5 mA (IB...IG used as discrete input circuit)
Voltage state 0 guaranteed<= 3 V for IB...IG used as discrete input circuit · <= 2.4 V for I1...IA and IH...IR discrete input circuit
Voltage state 1 guaranteed>= 7 V for IB...IG used as discrete input circuit · >= 5.6 V for I1...IA and IH...IR discrete input circuit
Maximum permissible voltage14.4 V for analogue input circuit
Reverse polarity protectionWith
Contacts type and compositionNO for relay output
Number or control scheme lines0…240 with ladder programming · 0…500 with FBD programming
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
What is the difference between on-delay and off-delay timers?

An on-delay timer switches its output after the set time once it receives power or a start signal, while an off-delay timer holds its output on for the set time after the signal is removed. Multifunction timers offer both and other modes such as cyclic and interval.

Which timer do I need for a star-delta starter?

A dedicated star-delta timer has a built-in short dead time between star and delta changeover to prevent a short circuit across contactors. The star time is set to suit how fast the motor reaches near full speed, often a few seconds to around 15 seconds.

What does a phase failure relay protect against?

A phase monitoring relay detects phase loss, phase reversal (wrong sequence) and often phase unbalance or under/over voltage, and trips the contactor coil to protect three-phase motors. It is especially useful for pumps, compressors and lifts where wrong rotation or single phasing can cause damage.

Can I use a timer to run a water pump automatically?

A cyclic or programmable timer can switch a pump contactor on and off at set intervals, but for tank level control a level controller relay with probes or a float switch is more reliable. The pump also needs proper motor protection like an MPCB or overload relay.

Do these mount on DIN rail?

Most modern timers and monitoring relays are DIN rail mounted (35mm), while some older or plug-in types use an 8-pin or 11-pin socket base. Check the mounting type and whether the base is included.

No reviews yet