🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Siemens Betagard 5SL7 MCB 32 A · 2 Pole · 15 kA · D-Curve · 5SL72328RC5SL72328RC↓ 40% off1 / 2
BrandSiemens
CategorySwitchgear
SpecificationMCB · 5SL7
Brand SKU5SL72328RC
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Siemens· In stock
Visit the Siemens store

Siemens Betagard 5SL7 MCB 32 A · 2 Pole · 15 kA · D-Curve · 5SL72328RC

$20.40/pc-40%
$34.00
Wholesale · 15+ units
$19.38 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$20.40 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
DP
32 A
-
15 kA
$20.40 /pc
Viewing above ↑
MCB
DP
32 A
-
-
$13.02 /pc
MCB
DP
32 A
C
-
$15.39 /pc
MCB
DP
32 A
D
-
$17.03 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $19.38/pc on this product, applied automatically

Siemens Betagard 5SL7 MCB 32 A (article 5SL72328RC) is a mcb from Siemens, 5SL7 series, sold by Elume with a GST invoice and pan-India delivery. Key data: manufacturer product name Miniature circuit breaker 415 V 2-pole 15 kA D 32, ampere/current rating 32 A, breaking capacity icu 15 kA, no. of poles 2 Pole, type AC MCB, tripping characteristic D-Curve, rated voltage (v) 415V AC. Priced at the Siemens India list price of 2026 (MRP before GST Rs 1,985), GST included in the price shown.

As published by Siemens. Verify critical parameters against the datasheet before specifying.
Siemens Siemens Betagard 5SL7 MCB 32 A · 2 Pole · 15 kA · D-Curve · 5SL72328RC · 5SL72328RC
Device typeMCB
Series5SL7
Poles2P (DP)
Rated current32 A
Trip curveD curve
Breaking capacity15 kA
Current rating32 A
Reference standardIS/IEC 60898-1
BrandSiemens
Brand SKU5SL72328RC
ELINE34DC6G3CM
Sold asPer pc
TypeAC MCB
No. Of Poles2 Pole
Rated Voltage (V)415V AC
Ampere/Current Rating32 A
Breaking Capacity Icu15 kA
Tripping CharacteristicD-Curve
Manufacturer Product NameMiniature circuit breaker 415 V 2-pole 15 kA D 32
Ratings as published by Siemens (eleczo.com listing; Siemens spec table; Elume). Verify critical parameters against the datasheet before specifying.
Other Siemens ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet