Schneider Acti9 Vigi xC60 Vigi Add-on RCD · 2P · 63 A · 100 mA · A9N26612A9N26612↓ 40% off
BrandSchneider
CategorySwitchgear
Specification2P · 63 A · 100 mA
Brand SKUA9N26612
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 Vigi xC60 Vigi Add-on RCD · 2P · 63 A · 100 mA · A9N26612

Rating: 63 A
Poles: 2P
Sensitivity: 100 mA
$169.51/pc-40%
$282.53
Wholesale · 15+ units
$161.04 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$169.51 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $161.04/pc on this product, applied automatically

This Acti9 Vigi xC60 is a modular add-on residual current devices. It is a 2P and rated current is 63A. The earth leakage protection class is AC type with a sensitivity of 100mA and a electromechanical technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. This product is compliant with EN/IEC 61009-1 and EN/IEC 61009-2-1 standard. The Ue rated operational voltage is from 230VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on DIN rail. The width in 9mm pitches is 4. The dimensions are (W) 72mm x (H) 87mm x (D) 74.5mm. The weight is 150g. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is -5°C to 60°C. The storage temperature is -40°C to 85°C.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 Vigi xC60 Vigi Add-on RCD · 2P · 63 A · 100 mA · A9N26612 · A9N26612
Poles2P (DP)
Rated current63 A
Sensitivity (IΔn)100 mA
Ingress protectionIP20· IP40 (modular enclosure)
Reference standardEN/IEC 61009-1
Net weight0.15 kg
Device typeMiniature circuit breaker (MCB)
Current rating63 A
BrandSchneider
Brand SKUA9N26612
ELINE2H44RM7MD
Sold asPer pc
Depth74.5 mm
RangeActi9
Width72 mm
Height87 mm
StandardsEN/IEC 61009-1 · EN/IEC 61009-2-1
9 mm pitches4
Network typeAC
Mounting modeClip-on
Local signallingRed indicator light on the front face
Mounting supportDIN rail
Pollution degree3
Device short nameVigi xC60
Network frequency50/60 Hz
Poles description2P
Tightening torque3.5 N.m bottom
[In] rated current63 A
Range compatibilityActi9 iC60
Wire stripping length14 mm for bottom connection
Connections - terminalsTunnel type terminal downside for 1 cable(s) 1…35 mm² rigid without cable end · Tunnel type terminal downside for 1 cable(s) 1…25 mm² flexible without cable end · Tunnel type terminal downside for 1 cable(s) 1…25 mm² flexible with cable end
IP degree of protectionIP20 conforming to IEC 60529 · IP40 (modular enclosure) conforming to IEC 60529
Device location in systemOutgoer
Earth-leakage sensitivity100 mA
Product or component typeAdd-on residual current device
Electrical connection to mcbBy screws
Earth leakage protection typeType AC
Electromagnetic compatibility8/20 µs impulse withstand, 250 A
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Ue] rated operational voltage230...240 V AC 50/60 Hz conforming to EN/IEC 61009-1 · 230...240 V conforming to EN/IEC 61009-2-1
Ambient air temperature for storage-40…85 °C
Earth-leakage protection time delayInstantaneous
Residual current tripping technologyElectromechanical · Voltage independent
Ambient air temperature for operation-5…60 °C
[Uimp] rated impulse withstand voltage6 kV
Ratings as published by Schneider (se.com; Schneider spec table). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

What sensitivity is this RCCB?

This RCCB trips at a residual (leakage) current of 100 mA. 30mA is the standard for personal shock protection, while 100mA and 300mA are used for equipment and fire protection.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

Is this a 2 pole or 4 pole RCCB?

The pole configuration of this RCCB is 2P. 2 pole is used on single-phase supply and 4 pole on three-phase supply with neutral, and the neutral of every protected circuit must pass through the same RCCB.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.