🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
3KX8430-0HF↓ 40% off
BrandSiemens
CategorySwitchgear
SpecificationSwitch disconnector
Brand SKU3KX8430-0HF
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Siemens· In stock
Visit the Siemens store

Siemens Superswitch Fuse Cover · 2P · BS HRC fuses · For 3KL84 & 3KA84 · 3KX8430-0HF

$30.16/pc-40%
$50.27
Wholesale · 15+ units
$28.66 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$30.16 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $28.66/pc on this product, applied automatically

Siemens Fuse Cover Suitable For 3KL84 11/21/31 (article 3KX8430-0HF) is a switch disconnector from Siemens, sold by Elume with a GST invoice and pan-India delivery. Priced at the Siemens India list price of 2026 (MRP before GST Rs 2,935), GST included in the price shown.

As published by Siemens. Verify critical parameters against the datasheet before specifying.
Siemens Siemens Superswitch Fuse Cover · 2P · BS HRC fuses · For 3KL84 & 3KA84 · 3KX8430-0HF · 3KX8430-0HF
Device typeSwitch disconnector
Poles2P (DP)
Reference standardIEC 60947-3
BrandSiemens
Brand SKU3KX8430-0HF
ELINE2GJHFP6F6
Sold asPer pc
Devicefuse cover
Fuse typeBS HRC fuses
For use withSuperswitch 3KL84 & 3KA84
Ratings as published by Siemens (Siemens spec table; Elume). Verify critical parameters against the datasheet before specifying.
Other Siemens ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between SFU and FSU?

In a switch fuse unit (SFU), the fuses are fixed and the switch contacts operate separately, while in a fuse switch unit (FSU) the fuses are mounted on the moving part, so they are isolated on both sides when opened. FSUs are generally considered safer for fuse replacement; both are covered by IS/IEC 60947-3.

Should I replace old rewirable (kit-kat) fuses with MCBs?

Yes, in most homes it is recommended. Rewirable fuses are often refilled with the wrong wire and are slow and inconsistent, while MCBs give reliable, resettable protection; upgrading to an MCB DB with an RCCB also adds shock protection.

Can I use a fuse switch as a main switch for a motor?

Yes, fuse switches are widely used as incomers for motor feeders, typically with aM or gG HRC fuses sized to withstand the motor's starting current. The motor still needs a contactor and overload relay or a motor starter for overload protection.

Does this unit come with fuses?

Many fuse switches and switch fuse units are sold without fuse links, which are bought separately to suit the load. Check the package contents listed on the product page before ordering.

Why does a fuse keep blowing?

Repeated blowing usually means a short circuit, an overloaded circuit or a fuse rated too low for the starting current of motors. Never replace with a higher rating or wire without finding the cause; have an electrician check the load and wiring.

No reviews yet