Schneider Acti9 Phase Segregated Distribution Board · 6 ways · 46 modules · split door · IP43 · surface mount · White (RAL 9003) · A9HPSG06A9HPSG06↓ 40% off
BrandSchneider
CategoryDB & Panels
Specification46 modules · split door · IP43 · surface mount
Brand SKUA9HPSG06
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 Phase Segregated Distribution Board · 6 ways · 46 modules · split door · IP43 · surface mount · White (RAL 9003) · A9HPSG06

$227.09/pc-40%
$378.48
Wholesale · 15+ units
$215.73 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$227.09 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $215.73/pc on this product, applied automatically

Acti9 PSG 6 ways surface or flush mount Distribution board designed for safe, efficient, and modular power distribution. It includes 46 modules (18 mm pitch) and is rated for 63 A. The enclosure is designed for surface or flush mounting and includes. It features a split-door metal enclosure IP43 protection rating, offering protection against solid objects and water spray, making it suitable for indoor installations.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 Phase Segregated Distribution Board · 6 ways · 46 modules · split door · IP43 · surface mount · White (RAL 9003) · A9HPSG06 · A9HPSG06
Ways6 way
Rated current63 A
Ingress protectionIP43
ColourWhite (RAL 9003)
Reference standardIS 8623-1
Net weight16.33 kg
Enclosure typeDistribution board - SPN (single phase)
BrandSchneider
Brand SKUA9HPSG06
ELINE2DD99GP62
Sold asPer pc
DepthExternal : 98.6 mm
RangeActi9
WidthExternal: 602 mm
HeightExternal: 607.2 mm
StandardsIS 8623-1 · IS 8623-3 · IEC 61439-3
Product namePhase Segregated
Number of ways6 ways
Door opening sideReversible
Device applicationDistribution
Enclosure materialGalvanized steel box · Galvanized steel DIN rail · Galvanized steel cable gland plate · CRCA door · CRCA central plate · CRCA frame
Enclosure mountingSurface · Flush
Provided equipmentRemovable gland plates · Removable centre plates · Removable frame · Grounding bar · Neutral bar · Busbar · Cable · Rotary lock
[In] rated current63 A
Product certificationsNABL
Protection device typeMain incomer: isolator - 4P · Main incomer: miniature circuit breaker (MCB) - 4P · Sub feeder: residual current circuit breaker (RCCB) - 2P (phase) · Sub feeder: residual current circuit breaker with overcurrent protection (RCBO) - 2P (phase) · Outgoer: miniature circuit breaker (MCB) - 1P
IK degree of protectionIK09
IP degree of protectionIP43
Product or component typeDistribution board
Enclosure/cubicle descriptionSplit door enclosure
Total number of 18 mm modules46
Ratings as published by Schneider (Schneider spec table; se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: How Many Ways Should Your Distribution Board Have? 4, 8, 12 or 16 Way Explained →
What does 8 way or 12 way mean in a distribution board?
The number of single-module slots on the outgoing rail. Each single-pole MCB uses one way; wider devices like a double-pole RCCB use two or more. The usable circuit count is therefore the way count minus the width of incomer and protection devices.
How many ways do I need for a 2BHK?
Usually 8 to 12: two lighting circuits, two socket circuits, kitchen power, plus dedicated ways per AC and geyser, the RCCB's two ways, and spares. Buy 12 if the kitchen is appliance-heavy or an AC may be added later.
What is the difference between SPN and TPN distribution boards?
SPN boards serve single-phase (230 V) supplies with one phase busbar. TPN boards serve three-phase (415 V) supplies with three phase sections plus neutral, letting circuits balance across phases. Your electricity connection type decides which you need.
What does SPN mean in a distribution board?

SPN stands for Single Pole and Neutral, a DB for single-phase supply with a phase busbar, a neutral link and an earth bar. It is the standard DB for most Indian homes and small shops with single-phase connections.

How many ways do I need for a 2BHK or 3BHK flat?

Count one way per circuit (lighting, sockets, each AC, geyser, kitchen, etc.) plus incomer space, then add about 20-30% spare for future loads. A typical 2BHK uses around 8-12 ways and a 3BHK around 12-16 ways, but your circuit plan decides it.

Can I install an RCCB in this DB?

Most SPN DBs have incomer space for a DP MCB or isolator plus a 2-module RCCB, but this depends on the board. Check the incomer configuration, or choose an RCCB-ready DB if you want shock protection for all circuits.

Is flush mounting or surface mounting better?

Flush (concealed) DBs are recessed into the wall and suit new construction or renovation, while surface-mounted DBs are fixed on the wall and easier to retrofit. Measure the wall depth before choosing a flush DB.

Does the DB come with MCBs?

Most distribution boards are sold empty with busbar, neutral link and earth bar, and MCBs are bought separately. Check the package contents on the product page.

No reviews yet