Crompton ARMOR1.0-CQU Single Phase Control Panel · 1 HP · WhiteARMOR1.0-CQU↓ 28% off MRP1 / 5
BrandCrompton
CategoryDB & Panels
SpecificationARMOR1.0-CQU - Single Phase Control Panel 1 HP · White
Brand SKUARMOR1.0-CQU
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Crompton· In stock
Visit the Crompton store

Crompton ARMOR1.0-CQU Single Phase Control Panel · 1 HP · White

₹2,988/pcincl. GST-28%
₹2,532 + 18% GST · MRP ₹4,150
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹2,988 /pc incl. GST
Free delivery over ₹4,000

Crompton ARMOR1.0-CQU Single Phase Control Panel · 1 HP · White: Elume price today ₹2,988 per pc incl. GST, 28% below the ₹4,150 MRP. Today's price is the lowest of the last 30 days (high ₹4,109). The average price across the sellers we track is ₹4,150, ₹1,162 more than here. The lowest tracked seller lists it at ₹4,150, ₹1,162 above the Elume price.

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹4,616₹4,065₹3,513₹2,962₹2,411₹4,150₹4,150₹2,988
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
✓₹1,162 lower than the market price
Elume today
₹2,988
Avg market price
₹4,150
MRP
₹4,150
Lowest in view · 20 Sep
₹2,592
Highest in view · 3 Oct
₹4,314
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹2,839/pc on this product, applied automatically

The Crompton Armor water pump is your trusted partner for a steady and hassle-free water supply. Designed for homes with fluctuating power, its Wide Voltage Application ensures seamless performance even in varying voltage conditions. With Dry Run Protection, the pump intelligently stops operation when water levels are low, thanks to its advanced float switch, safeguarding the pump from damage. Eff

  • Dry Run Protection
  • Settable Off Timer
  • Overload Protection
  • 12 Month
  • Armor
  • Wide Voltage Application
High Suction Capacity
Wide voltage design
Easy Maintenance
As published by Crompton. Verify critical parameters against the datasheet before specifying.
Crompton Crompton ARMOR1.0-CQU Single Phase Control Panel · 1 HP · White · ARMOR1.0-CQU
PhaseSingle phase (SPN)
ColourWhite
Dimensions242 x 102 x 197 mm
Net weight2.19 kg
Warranty1 year
Rated voltage120-260 V
Wattage0.75 W
Power1 HP
Enclosure typeDistribution board - SPN (single phase)
Reference standardIS 8623 / IEC 61439
BrandCrompton
Brand SKUARMOR1.0-CQU
ELINEPM34HDG23
Sold asPer pc
ColorWhite
ModelARMOR1-CQU
Weight2.19 Kilograms
Voltage120-260
Horsepower1
Unit Count1
Product Description0.75KW/1HP 1PH BW CROMPTON ARMOR CP-U
Power and Plug DescriptionAC
Ratings as published by Crompton (Product name; Elume catalogue; crompton.co.in). Verify critical parameters against the datasheet before specifying.
Read: How Many Ways Should Your Distribution Board Have? 4, 8, 12 or 16 Way Explained →
What does 8 way or 12 way mean in a distribution board?
The number of single-module slots on the outgoing rail. Each single-pole MCB uses one way; wider devices like a double-pole RCCB use two or more. The usable circuit count is therefore the way count minus the width of incomer and protection devices.
How many ways do I need for a 2BHK?
Usually 8 to 12: two lighting circuits, two socket circuits, kitchen power, plus dedicated ways per AC and geyser, the RCCB's two ways, and spares. Buy 12 if the kitchen is appliance-heavy or an AC may be added later.
What is the difference between SPN and TPN distribution boards?
SPN boards serve single-phase (230 V) supplies with one phase busbar. TPN boards serve three-phase (415 V) supplies with three phase sections plus neutral, letting circuits balance across phases. Your electricity connection type decides which you need.
What does SPN mean in a distribution board?

SPN stands for Single Pole and Neutral, a DB for single-phase supply with a phase busbar, a neutral link and an earth bar. It is the standard DB for most Indian homes and small shops with single-phase connections.

How many ways do I need for a 2BHK or 3BHK flat?

Count one way per circuit (lighting, sockets, each AC, geyser, kitchen, etc.) plus incomer space, then add about 20-30% spare for future loads. A typical 2BHK uses around 8-12 ways and a 3BHK around 12-16 ways, but your circuit plan decides it.

Can I install an RCCB in this DB?

Most SPN DBs have incomer space for a DP MCB or isolator plus a 2-module RCCB, but this depends on the board. Check the incomer configuration, or choose an RCCB-ready DB if you want shock protection for all circuits.

Is flush mounting or surface mounting better?

Flush (concealed) DBs are recessed into the wall and suit new construction or renovation, while surface-mounted DBs are fixed on the wall and easier to retrofit. Measure the wall depth before choosing a flush DB.

Does the DB come with MCBs?

Most distribution boards are sold empty with busbar, neutral link and earth bar, and MCBs are bought separately. Check the package contents on the product page.