ABB OVR T2 3N 40-320 P TS U Surge Protective Device · 2CTB802346R25002CTB802346R2500↓ 15% off MRP
BrandABB
CategorySwitchgear
SpecificationOVR T2 3N 40-320 P TS U Surge Protective Device
Brand SKU2CTB802346R2500
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB OVR T2 3N 40-320 P TS U Surge Protective Device · 2CTB802346R2500

₹34,955/pcincl. GST-15%
₹29,623 + 18% GST · MRP ₹41,197
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹34,955 /pc incl. GST
Delivery ₹1,000, ships insured

ABB OVR T2 3N 40-320 P TS U Surge Protective Device · 2CTB802346R2500: Elume price today ₹34,955 per pc incl. GST, 15% below the ₹41,197 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹27,964, ₹6,991 less than here.

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹44,081₹39,280₹34,478₹29,677₹24,876₹41,197₹34,955₹27,964
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹34,955
Avg market price
₹27,964
MRP
₹41,197
Lowest in view · 10 Aug
₹26,748
Highest in view · 3 Oct
₹41,197
For solar installers
Buying this for a rooftop solar job?
The price above is for a single piece. Send the whole requirement in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹33,207/pc on this product, applied automatically

ABB OVR T2 3N 40-320 P TS U Surge Protective Device is an SPD from ABB. It diverts lightning and switching surges to earth so that the equipment downstream survives them. Key ratings: Poles 4P (FP), Uc (L-PE) 320 V, Width 4 M (71.2 mm), Ingress protection IP20. It is built to UL 1449 Ed3.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB OVR T2 3N 40-320 P TS U Surge Protective Device · 2CTB802346R2500 · 2CTB802346R2500
Device typeSurge protection device (SPD)
Poles4P (FP)
Max continuous operating voltage (Uc)(L-PE) 320 V
Voltage protection level (Up)1.2 kV
Service breaking capacity (Ics)100 kA
Width4 modules (71.2 mm)
Ingress protectionIP20
Reference standardUL 1449 Ed3
Net weight0.48 kg
BrandABB
Brand SKU2CTB802346R2500
ELINEC9G992G3P
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 2CTC432139D1701). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which type of SPD should I use for my home - Type 1 or Type 2?

For most homes and apartments, a Type 2 SPD in the main DB is the standard choice. Type 1 or combined Type 1+2 is used at the service entrance of independent houses in lightning-prone areas or buildings with external lightning protection (SPDs are covered by IS 16463 (Part 11), identical to IEC 61643-11).

Does an SPD need earthing?

Yes. An SPD diverts surge energy to earth, so it works only with a proper, low-resistance earth connection kept as short as possible. Without good earthing it gives little or no protection.

Will an SPD protect against high voltage from neutral failure?

No. SPDs are designed for short transient surges from lightning and switching, not sustained overvoltage such as from a broken neutral or poor supply. For that, use a voltage protection relay, an over/under voltage protector or stabilisers for sensitive equipment.

How do I know when the SPD needs replacing?

Most SPDs have an indicator window that turns from green to red when the protective element has reached end of life. Pluggable SPDs allow replacing only the cartridge; check the indicator periodically and after major thunderstorms.

Does an SPD need an MCB or fuse before it?

Yes, an SPD should have backup protection (MCB or fuse) as specified by the manufacturer, so a failed SPD can be safely disconnected without tripping the whole installation. The backup rating is usually listed in the SPD datasheet.

What do Imax, In and Up mean on an SPD?

Imax is the maximum surge current it can discharge once, In is the nominal current it can handle repeatedly, and Up is the voltage protection level (the let-through voltage), where lower is better. For 230 V homes, a Type 2 SPD with Imax around 40kA and a maximum continuous operating voltage (Uc) of 275 V or more is commonly used.

No reviews yet