🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB RT5/90 Surge Suppressor · 1SBN050020R10021SBN050020R1002↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationRT5/90 · AL Contactors
Brand SKU1SBN050020R1002
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB RT5/90 Surge Suppressor · 1SBN050020R1002

NEW added this week
₹887/pcincl. GST-53%
₹752 + 18% GST · MRP ₹1,880
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹887 /pc incl. GST
Free delivery over ₹4,000

ABB RT5/90 Surge Suppressor · 1SBN050020R1002: Elume price today ₹887 per pc incl. GST, 53% below the ₹1,880 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹2,012₹1,715₹1,418₹1,122₹825₹1,880₹887
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹887
MRP
₹1,880
Lowest in view · 17 Nov
₹887
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹869/pc on this product, applied automatically

RT5/90 is a transil diode surge suppressor designed to reduce the maximum overvoltage peak value and to limit or even completely eliminate the high pre-damping voltage frequencies, when used or with a DC operated conventional contactor for a rated control circuit voltage between 50 ... 90 V DC. The operation of inductive circuits causes overvoltages, in particular on opening of the contactor coil. The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed ranging from interference on the electronic devices to breakdown of insulators and even destruction of certain sensitive components. Advantages: - the surge suppressor is clipped onto the top or side part in regards with the contactor or contactor relay base design without change in device overall dimensions. - good energy absorption - Unpolarized system - Simple, reliable system - very fast clipping: attenuation of steep fronts and thus of high frequencies. No operating delays. Drawback: a certain delay on drop out which does not however reduce contactor breaking capacity.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB RT5/90 Surge Suppressor · 1SBN050020R1002 · 1SBN050020R1002
SeriesAL Contactors
Country of originChina
Device typeMiniature circuit breaker (MCB)
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBN050020R1002
ELINE3HJJJ7KP9
Sold asPer pc
Mounting TypeClipped onto the top or side part of the contactor or contactor relay base without change in device overall dimensions.
Package Width65 mm
Product ClassBlock Contactors Accessories
Package Height12 mm
Package Length96 mm
Package Gross Weight0.03 kg
Extended Product TypeRT5/90
Ambient Air TemperatureOperation -20 ... +70 °C
Rated Control Circuit Voltage (Uc)DC Operation 50-90 2HV
Product RangeAL Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SBN050020R1002, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which type of SPD should I use for my home - Type 1 or Type 2?

For most homes and apartments, a Type 2 SPD in the main DB is the standard choice. Type 1 or combined Type 1+2 is used at the service entrance of independent houses in lightning-prone areas or buildings with external lightning protection (SPDs are covered by IS 16463 (Part 11), identical to IEC 61643-11).

Does an SPD need earthing?

Yes. An SPD diverts surge energy to earth, so it works only with a proper, low-resistance earth connection kept as short as possible. Without good earthing it gives little or no protection.

Will an SPD protect against high voltage from neutral failure?

No. SPDs are designed for short transient surges from lightning and switching, not sustained overvoltage such as from a broken neutral or poor supply. For that, use a voltage protection relay, an over/under voltage protector or stabilisers for sensitive equipment.

How do I know when the SPD needs replacing?

Most SPDs have an indicator window that turns from green to red when the protective element has reached end of life. Pluggable SPDs allow replacing only the cartridge; check the indicator periodically and after major thunderstorms.

Does an SPD need an MCB or fuse before it?

Yes, an SPD should have backup protection (MCB or fuse) as specified by the manufacturer, so a failed SPD can be safely disconnected without tripping the whole installation. The backup rating is usually listed in the SPD datasheet.

What do Imax, In and Up mean on an SPD?

Imax is the maximum surge current it can discharge once, In is the nominal current it can handle repeatedly, and Up is the voltage protection level (the let-through voltage), where lower is better. For 230 V homes, a Type 2 SPD with Imax around 40kA and a maximum continuous operating voltage (Uc) of 275 V or more is commonly used.

No reviews yet