ABB MO165-16 Manual Motor Starter Magnetic Only · 1SAM461000R10111SAM461000R1011↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationMO165-16 · MO-MS
Brand SKU1SAM461000R1011
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB MO165-16 Manual Motor Starter Magnetic Only · 1SAM461000R1011

NEW added this week
₹14,605/pcincl. GST-53%
₹12,377 + 18% GST · MRP ₹30,944
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹14,605 /pc incl. GST
Free pan-India delivery

ABB MO165-16 Manual Motor Starter Magnetic Only · 1SAM461000R1011: Elume price today ₹14,605 per pc incl. GST, 53% below the ₹30,944 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹33,110₹28,228₹23,346₹18,465₹13,583₹30,944₹14,605
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹14,605
MRP
₹30,944
Lowest in view · 17 Nov
₹14,605
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹13,875/pc on this product, applied automatically

The MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB MO165-16 Manual Motor Starter Magnetic Only · 1SAM461000R1011 · 1SAM461000R1011
Device typeManual motor starter (MPCB)
SeriesMO-MS
Poles3P (TP)
Rated current16 A
Frequency50 Hz/Main Circuit 60 Hz
Service breaking capacity (Ics)100 kA
Operational current (Ie)16A
Insulation voltage (Ui)1000 V
Country of originChina
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SAM461000R1011
ELINE73H74M23R
Sold asPer pc
Package Width78 mm
Terminal TypeScrew Terminals
Package Height155 mm
Package Length155 mm
Number of Poles3
Rated Current (In)16A
Rated Frequency (f)Main Circuit 50 Hz/Main Circuit 60 Hz
Package Gross Weight1.1 kg
Extended Product TypeMO165-16
Ambient Air TemperatureOperation -25 ... +60 °C, Operation Compensated -25 ... +60 °C, Storage -50 ... +80 °C
Full Load Amps Motor Use(200 V AC) Three Phase 11 A, (208 V AC) Three Phase 10.6 A, (220 ... 240 V AC) Three Phase 15.2 A, (440 ... 480 V AC) Three Phase 14 A, (550 ... 600 V AC) Three Phase 11 A
General Use Rating UL/CSA(600 V AC) 16 A
Max Operating Voltage UL/CSAMain Circuit 600 V AC
Rated Insulation Voltage (Ui)1000 V
Rated Operational Current (Ie)16A
Automation & Control Rated Operational VoltageMain Circuit 690 V AC/Main Circuit 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA, (250 V DC) 3 Poles in Series 100 kA, (400 V AC) 100 kA, (440 V AC) 75 kA, (500 V AC) 40 kA, (690 V AC) 8 kA
Product RangeMO-MS
Ratings as published by ABB (shop.in.abb.com listing for 1SAM461000R1011, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
No reviews yet