🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB TA25DU-4.0M Thermal Overload Relays · 1SAZ211201R20331SAZ211201R2033↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationTA25DU-4.0M · TA-TF
Brand SKU1SAZ211201R2033
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB TA25DU-4.0M Thermal Overload Relays · 1SAZ211201R2033

NEW added this week
₹1,844/pcincl. GST-53%
₹1,563 + 18% GST · MRP ₹3,906
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹1,844 /pc incl. GST
Free delivery over ₹4,000

ABB TA25DU-4.0M Thermal Overload Relays · 1SAZ211201R2033: Elume price today ₹1,844 per pc incl. GST, 53% below the ₹3,906 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹4,179₹3,563₹2,947₹2,331₹1,715₹3,906₹1,844
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹1,844
MRP
₹3,906
Lowest in view · 17 Nov
₹1,844
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹1,752/pc on this product, applied automatically

TA25DU-4.0M (2.8-4.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB TA25DU-4.0M Thermal Overload Relays · 1SAZ211201R2033 · 1SAZ211201R2033
Device typeThermal overload relay
SeriesTA-TF
Poles3P (TP)
FrequencyAuxiliary Circuit 50 Hz/Auxiliary Circuit 60 Hz/Auxiliary Circuit DC, Main Circuit 60 Hz/Main Circuit 50 Hz/Main Circuit DC
Operational current (Ie)4A
Setting range2.80-4.00A
Insulation voltage (Ui)690 V
Country of originBulgaria
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SAZ211201R2033
ELINEHDF2442KP
Sold asPer pc
Mounting TypeMounted on Contactor
Package Width98 mm
Terminal TypeScrew Terminals
Package Height82 mm
Package Length47 mm
Number of Poles3
Rated Frequency (f)Auxiliary Circuit 50 Hz/Auxiliary Circuit 60 Hz/Auxiliary Circuit DC, Main Circuit 60 Hz/Main Circuit 50 Hz/Main Circuit DC
Setting Range (OLR)2.80-4.00A
Ampere Rating UL/CSA4 A
Package Gross Weight0.17 kg
Extended Product TypeTA25DU-4.0M
Ambient Air TemperatureOperation -25 ... +55 °C, Operation Compensated -25 ... +55 °C, Storage -40 ... +70 °C
Number of Aux Contacts NC1
Number of Aux Contacts NO1
Max Operating Voltage UL/CSAMain Circuit 600 V AC
Rated Insulation Voltage (Ui)690 V
Rated Operational Current (Ie)4A
Automation & Control Rated Operational VoltageAuxiliary Circuit 440/500 V AC / DC, Main Circuit 690 V AC
Product RangeTA-TF
Ratings as published by ABB (shop.in.abb.com listing for 1SAZ211201R2033, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What should I set the overload relay to?

Set it to the motor's full-load current from the nameplate, not higher. In a star-delta starter where the relay is in the phase winding circuit, it is set to about 0.58 times the full-load current.

Will this overload relay fit my contactor?

Most overload relays are designed to mount directly on specific contactor sizes of the same brand and range. For other brands or sizes, a separate mounting kit or panel mounting is needed, so check the compatibility list.

Does it protect against single phasing?

Most modern thermal overload relays have differential (single phasing) sensitivity and trip faster when one phase is lost, which helps protect three-phase motors. For full phase failure and phase reversal protection, a phase monitoring relay is also recommended.

What is trip class 10 and class 20?

Trip class indicates the maximum time to trip from cold at 7.2 times the set current: class 10 trips within 10 seconds and class 20 within 20 seconds (IS/IEC 60947-4-1). Class 10 suits normal motors, while class 20 or 30 is used for heavy-starting loads like crushers and fans with large inertia.

What is the difference between manual and auto reset?

In manual reset, someone must press the reset button after a trip, while auto reset lets the relay reset itself once it cools. Manual reset is generally safer, since the motor will not restart unexpectedly.

No reviews yet