🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Polycab Optima+ House Wire · LF FR · 1.0 sq mm · 90 m · White↓ 48% off MRP1 / 2
BrandPolycab
CategoryWires & Cables
Specification1.0 sq mm · single core · 14/0.31 strand bright annealed copper · 90 m coil · LF FR PVC · 70°C · lead free · 1100 V · IS 694
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Polycab· In stock
Visit the Polycab store

Polycab Optima+ House Wire · LF FR · 1.0 sq mm · 90 m · White

Size: 1.0 sq mm
Colour: White
Length: 90 m
₹2,293/coilincl. GST-48%
₹1,943 + 18% GST · MRP ₹4,410
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹2,293 /coil incl. GST
Free delivery over ₹4,000
From the Polycab range

Polycab Optima+

LF FR · High quality materials, power saving design · 90 m and 180 m coils

Polycab Optima+ is a lead free flame retardant (LF FR) house wire with an energy saving construction, moisture resistance and rodent protection.

  • Lead free flame retardant (LF FR) PVC insulation
  • Maximum operating temperature 70 °C
  • 99.97% high purity bright annealed electrolytic copper
  • Single core, 1100 V grade, IS 694:2010
Moisture resistantRodent protectionHigh abrasion resistanceEnergy saving constructionLead free PVC insulationFlame retardantRoHS and REACH compliant99.97% high purity copper
As published by Polycab on polycab.com and in the House Wires & Cables Catalogue (March 2025).
Polycab Optima+ page from the Polycab House Wires & Cables Catalogue, March 2025Open the catalogue page ›Polycab House Wires & Cables Catalogue, March 2025

Polycab Optima+ House Wire · LF FR · 1.0 sq mm · 90 m · White: Elume price today ₹2,293 per coil incl. GST, 48% below the ₹4,410 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
24 Aug to 22 Nov
₹4,719₹4,047₹3,375₹2,703₹2,031₹4,410₹2,293
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Elume today
₹2,293
MRP
₹4,410
Lowest in view · 16 Sep
₹2,184
Highest in view · 3 Oct
₹2,293
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.
Product
Size
Coil length
Insulation
Cores
Voltage grade
Price
1 sq mm
90 m
FR
Single core
1100 V
₹1,943 +GST /coil
₹2,293 incl. GST
Viewing above ↑
1 sq mm
90 m
FR
Single core
1100 V
₹1,550 +GST /coil
₹1,829 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹1,901 +GST /coil
₹2,243 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹1,943 +GST /coil
₹2,293 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹1,514 +GST /coil
₹1,787 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹1,736 +GST /coil
₹2,048 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹1,799 +GST /coil
₹2,123 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹1,819 +GST /coil
₹2,146 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹1,822 +GST /coil
₹2,150 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹2,136 +GST /coil
₹2,520 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹2,180 +GST /pc
₹2,572 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹2,186 +GST /coil
₹2,580 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹2,186 +GST /coil
₹2,580 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹2,329 +GST /pc
₹2,748 incl. GST
1 sq mm
90 m
FR
Single core
1100 V
₹2,517 +GST /pc
₹2,970 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹2,178/coil on this product, applied automatically

POLYCABOPTIMA+ flame retardant and lead free wires bring together the highest quality raw materials in a power saving design. POLYCABOPTIMA+ wires have a high degree of flame retardance, abrasion and chemical resistance and are made using electrolytic grade copper of the highest quality.

  • Flame retardant
  • Lead free PVC insulation
  • Energy saving construction
  • Rodent protection
  • Mositure protection
  • High abrasion resistance
  • RoHS compliant
  • REACH complaint
  • 99.97% high purity copper
As published by Polycab. Verify critical parameters against the datasheet before specifying.

Technical data · Optima+

ConductorBright annealed electrolytic copper
Strand construction14/0.31 (no./mm)
InsulationLF FR PVC
Insulation thickness0.6 mm
Overall diameter2.44 mm
Current-carrying capacity11.6–12.6 A
Max conductor resistance18.1 Ω/km at 20°C
Max operating temp70°C
Voltage grade1100 V
StandardsIS 694:2010
Packing90 m coil
Polycab Polycab Optima+ House Wire · LF FR · 1.0 sq mm · 90 m · White
Device typeHouse wire
SeriesOptima+
Conductor size1 sq mm
CoresSingle core
ConductorBright annealed electrolytic copper
Strand construction14/0.31
InsulationLF FR
Voltage grade1100 V
Current-carrying capacity11.6–12.6 A
Max conductor temperature70 °C
Length90 m
ColourWhite
Reference standardIS 694:2010
Coil length90 m
Core colourWhite
ApplicationFixed internal wiring - conduit & casing-capping
BrandPolycab
ELINEP63GC6KKP
Sold asPer coil
Ratings as published by Polycab (Polycab House Wires Catalogue (Mar-25); polycab.com). Verify critical parameters against the datasheet before specifying.
Effective price
₹22/m +GST
Wholesale (15+ coils)
₹21/m +GST
MRP equivalent
₹49/m incl.
Read: Importing Electrical Goods for a Project: Incoterms, Documents and Lead Times Explained →
What is the difference between FOB and CIF?
Under FOB the seller's job ends when the goods are loaded on the vessel at the origin port; you pay the freight and insurance. Under CIF the seller also pays the freight and minimum insurance to your destination port, but the risk still passes to you at loading.
Which Incoterm should I use for courier shipments?
DAP is the usual choice: the seller delivers to your door and you clear import duties. FCA or CPT also work if you prefer to arrange or control the carriage yourself.
Do I need a certificate of origin?
You need it to claim preferential duty under a trade agreement, and some importing countries ask for it on every shipment. Ask for it with the quote so it is issued before dispatch.
FR vs FRLS vs HFFR / ZHFR - which wire should I buy for my home?

FR (flame retardant) slows the spread of fire; FRLS also gives off much less smoke; HFFR / ZHFR (halogen free) additionally avoids toxic, corrosive halogen gases when it burns. FRLS is a sensible minimum for homes, and halogen-free wire is worth it for bedrooms, escape routes and enclosed spaces if the budget allows.

Which wire size should I use for lights, sockets, AC and geyser?

Common practice in Indian homes is 1.5 sq mm for lights and fans, 2.5 sq mm for 6A/16A socket circuits, 4 sq mm on a dedicated circuit for a 1.5 ton AC or geyser, and 6 sq mm or more for the main supply to the distribution board. Long runs and higher loads need a bigger size, so have a licensed electrician confirm sizes against the MCB ratings.

What size is this wire and what is it suitable for?

The listed size of this wire is 1.0 sq mm. As a rule of thumb, 1-1.5 sq mm suits lighting, 2.5 sq mm suits socket circuits, 4 sq mm suits AC or geyser circuits and 6 sq mm and above suits mains and sub-mains; always match the wire to the MCB rating and have a licensed electrician confirm.

How can I check the length of a wire coil?

The declared length is printed on the pack, and many brands also print running metre marks on the insulation, so you can compare the start and end readings.

How do I check the wire is genuine and ISI marked?

Look for the ISI mark with a CM/L licence number printed on the wire and the pack. You can verify the licence number on the BIS Care app; PVC-insulated house wires are made to IS 694.

Which colour wire should be used for phase, neutral and earth?

In Indian fixed wiring, red is used for phase (with yellow and blue for the other phases on three-phase supply), black for neutral and green or green-yellow for earth. Sticking to these colours makes future maintenance safer and is what electricians expect.

Is copper wire better than aluminium for house wiring?

Yes, copper is the standard for internal house wiring because it carries more current for the same size, is more flexible and makes more reliable joints. Aluminium is mainly used for larger supply and armoured cables.

Does a higher temperature rating (HR, 85 or 105 deg C) matter?

Standard PVC wire is rated for 70 deg C conductor temperature, while heat-resistant grades handle higher temperatures and age more slowly under heavy, continuous loads. It is useful for kitchens, AC and geyser circuits and hot roof slabs, but it does not replace choosing the correct wire size.

No reviews yet