🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
RR Kabel Q1 House Wire · FR · 4.0 sq mm · 90 m · Blue012101060420↓ 47% off MRP1 / 2
BrandRR Kabel
CategoryWires & Cables
Specification4.0 sq mm · single core · 56/0.31 strand electrolytic copper (IS 8130 class 5) · 90 m coil · FR PVC (IS 5831 Type D) · LOI >29% · 1100 V · IS 694 · Blue
Brand SKU012101060420
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
RR Kabel· In stock★5.0(1)
Visit the RR Kabel store

RR Kabel Q1 House Wire · FR · 4.0 sq mm · 90 m · Blue

Size: 4.0 sq mm
Colour: Blue
Length: 90 m
₹7,704/coilincl. GST-47%
₹6,529 + 18% GST · MRP ₹14,553
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹7,704 /coil incl. GST
Free pan-India delivery

RR Kabel Q1 House Wire · FR · 4.0 sq mm · 90 m · Blue: Elume price today ₹7,704 per coil incl. GST, 47% below the ₹14,553 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
24 Aug to 22 Nov
₹15,572₹13,275₹10,978₹8,681₹6,384₹14,553₹7,704
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Elume today
₹7,704
MRP
₹14,553
Lowest in view · 22 Sep
₹6,864
Highest in view · 14 Oct
₹7,704
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.
Product
Size
Coil length
Insulation
Cores
Voltage grade
Price
4 sq mm
90 m
FR
Single core
1100 V
₹6,529 +GST /coil
₹7,704 incl. GST
Viewing above ↑
4 sq mm
90 m
FR
Single core
1100 V
₹6,570 +GST /coil
₹7,753 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹6,903 +GST /coil
₹8,146 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹5,411 +GST /coil
₹6,385 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹6,108 +GST /coil
₹7,207 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹6,413 +GST /coil
₹7,567 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹6,525 +GST /coil
₹7,699 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹6,570 +GST /coil
₹7,753 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹7,288 +GST /coil
₹8,600 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹7,288 +GST /coil
₹8,600 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹7,516 +GST /coil
₹8,869 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹7,997 +GST /pc
₹9,436 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹8,207 +GST /pc
₹9,684 incl. GST
4 sq mm
90 m
FR
Single core
1100 V
₹9,229 +GST /pc
₹10,890 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹7,319/coil on this product, applied automatically

RR Kabel Q1 Flame Retardant is a single-core flexible house wire: multi-drawn strands of electrolytic-grade copper (IS 8130 class 5, 56/0.31) under a specially formulated FR PVC insulation (IS 5831 Type D, 70 °C) that is lead and mercury free with anti-rodent and anti-termite properties. IS 694 marked and FIA/TAC approved, rated up to 1100 V for -15 °C to +70 °C, self-extinguishing with a limiting oxygen index above 29% and a temperature index above 250 °C. The 4.0 sq mm size carries 30 A in casing and 26 A concealed (IS 3961 Part V), with an overall diameter of 4.1 mm. This listing is the blue coil, packed as a 90 m coil in a protective carton; we also list it in red, yellow, black, green.

  • Super flexible multi-strand electrolytic copper conductor (IS 8130 class 5)
  • FR PVC insulation, self-extinguishing: limiting oxygen index above 29%, temperature index above 250 °C
  • Lead and mercury free, anti-rodent and anti-termite compound
  • IS 694 marked, FIA/TAC approved; REACH, RoHS, CE and CPR compliant
  • 1100 V grade, -15 °C to +70 °C
As published by RR Kabel. Verify critical parameters against the datasheet before specifying.

Technical data · Q1 Flame Retardant

Conductorbright annealed electrolytic copper, multi-drawn · class 5
Strand construction56/0.31 (no./mm)
InsulationFR PVC
Insulation thickness0.8 mm
Overall diameter4.1 mm
Current-carrying capacityundefined A
Max conductor resistance4.95 Ω/km at 20°C
Voltage grade1100 V
StandardsIS 694:2010, IS 8130, IS 5831, IS 3961 Part V
Packing90 m coil in a protective carton

Fire & safety test results

TestMethodSpecified value
Limited Oxygen IndexIS 10810 P-58> 29%
Limited Temperature IndexIS 10810 P-64> 250 °C
Available colours: Red, Yellow, Blue, Black, Green
RR Kabel RR Kabel Q1 House Wire · FR · 4.0 sq mm · 90 m · Blue · 012101060420
Conductor size4 sq mm
CoresSingle core
ConductorElectrolytic copper
InsulationFR PVC (flame retardant)
Voltage grade1100 V
Length90 m
ColourBlue
Coil length90 m
Core colourBlue
Reference standardIS 694:2010
ApplicationFixed internal wiring - conduit & casing-capping
BrandRR Kabel
Brand SKU012101060420
ELINEHHR44K6RP
Sold asPer coil
Pack90 m coil in a protective carton
MarkingQ1 FR
StandardsIS 694:2010, IS 8130, IS 5831; FIA/TAC approved; REACH, RoHS, CE, CPR
Current rating30 A in casing, 26 A concealed (IS 3961 Part V)
RR part number012101060420
Flame retardanceLOI > 29% (IS 10810 P-58), temperature index > 250 °C (IS 10810 P-64)
Overall diameter4.1 mm
Temperature range-15 °C to +70 °C
Max. DC resistance at 20 °C4.95 Ω/km
Ratings as published by RR Kabel (rrkabel.com; Elume catalogue). Verify critical parameters against the datasheet before specifying.
Effective price
₹73/m +GST
Wholesale (15+ coils)
₹69/m +GST
MRP equivalent
₹162/m incl.
Read: Importing Electrical Goods for a Project: Incoterms, Documents and Lead Times Explained →
What is the difference between FOB and CIF?
Under FOB the seller's job ends when the goods are loaded on the vessel at the origin port; you pay the freight and insurance. Under CIF the seller also pays the freight and minimum insurance to your destination port, but the risk still passes to you at loading.
Which Incoterm should I use for courier shipments?
DAP is the usual choice: the seller delivers to your door and you clear import duties. FCA or CPT also work if you prefer to arrange or control the carriage yourself.
Do I need a certificate of origin?
You need it to claim preferential duty under a trade agreement, and some importing countries ask for it on every shipment. Ask for it with the quote so it is issued before dispatch.
FR vs FRLS vs HFFR / ZHFR - which wire should I buy for my home?

FR (flame retardant) slows the spread of fire; FRLS also gives off much less smoke; HFFR / ZHFR (halogen free) additionally avoids toxic, corrosive halogen gases when it burns. FRLS is a sensible minimum for homes, and halogen-free wire is worth it for bedrooms, escape routes and enclosed spaces if the budget allows.

Which wire size should I use for lights, sockets, AC and geyser?

Common practice in Indian homes is 1.5 sq mm for lights and fans, 2.5 sq mm for 6A/16A socket circuits, 4 sq mm on a dedicated circuit for a 1.5 ton AC or geyser, and 6 sq mm or more for the main supply to the distribution board. Long runs and higher loads need a bigger size, so have a licensed electrician confirm sizes against the MCB ratings.

What size is this wire and what is it suitable for?

The listed size of this wire is 4.0 sq mm. As a rule of thumb, 1-1.5 sq mm suits lighting, 2.5 sq mm suits socket circuits, 4 sq mm suits AC or geyser circuits and 6 sq mm and above suits mains and sub-mains; always match the wire to the MCB rating and have a licensed electrician confirm.

How can I check the length of a wire coil?

The declared length is printed on the pack, and many brands also print running metre marks on the insulation, so you can compare the start and end readings.

How do I check the wire is genuine and ISI marked?

Look for the ISI mark with a CM/L licence number printed on the wire and the pack. You can verify the licence number on the BIS Care app; PVC-insulated house wires are made to IS 694.

Which colour wire should be used for phase, neutral and earth?

In Indian fixed wiring, red is used for phase (with yellow and blue for the other phases on three-phase supply), black for neutral and green or green-yellow for earth. Sticking to these colours makes future maintenance safer and is what electricians expect.

Is copper wire better than aluminium for house wiring?

Yes, copper is the standard for internal house wiring because it carries more current for the same size, is more flexible and makes more reliable joints. Aluminium is mainly used for larger supply and armoured cables.

Does a higher temperature rating (HR, 85 or 105 deg C) matter?

Standard PVC wire is rated for 70 deg C conductor temperature, while heat-resistant grades handle higher temperatures and age more slowly under heavy, continuous loads. It is useful for kitchens, AC and geyser circuits and hot roof slabs, but it does not replace choosing the correct wire size.

★5.0(1)
★5.0✓ VerifiedMili Ahuja · 20 Oct

Quick delivery, received products in 2 days from order