🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider Easy TeSys LC1E Power Contactor · 3P · 200 A AC-3 · Without aux · 415 V AC 50 Hz coil · LC1E200N5LC1E200N5↓ 40% off MRP1 / 5
BrandSchneider
CategoryIndustrial Control
Specification3P · 200 A AC-3 · Without aux · 415 V AC 50 Hz coil
Brand SKULC1E200N5
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Schneider· In stock
Visit the Schneider store

Schneider Easy TeSys LC1E Power Contactor · 3P · 200 A AC-3 · Without aux · 415 V AC 50 Hz coil · LC1E200N5

Rating: 200 A AC-3
Coil: 415 V AC 50 Hz coil
NEW added this week
₹55,780/pcincl. GST-40%
₹47,271 + 18% GST · MRP ₹92,966
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹55,780 /pc incl. GST
Delivery ₹1,000, ships insured

Schneider Easy TeSys LC1E Power Contactor · 3P · 200 A AC-3 · Without aux · 415 V AC 50 Hz coil · LC1E200N5: Elume price today ₹55,780 per pc incl. GST, 40% below the ₹92,966 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹99,474₹87,574₹75,675₹63,775₹51,875₹92,966₹55,780
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹55,780
MRP
₹92,966
Lowest in view · 19 Nov
₹55,780
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹52,991/pc on this product, applied automatically

EasyPact TVS contactor 3 poles for motor applications up to 200A 100kW@440V. It provides a 415V 50Hz AC coil, without built-in auxiliary contacts, power and control connections by screw clamp terminals. 168.5mm width for standard operating rates up to 1200 cycles per hour. It procures standard reliability and durability with 0.5 Mcycles electrical durability AC-3 and 5 Mcycles mechanical durability. It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Easy TeSys LC1E Power Contactor · 3P · 200 A AC-3 · Without aux · 415 V AC 50 Hz coil · LC1E200N5 · LC1E200N5
Poles3P (TP)
Rated current200 A
Ingress protectionIP2X
Reference standardEN/IEC 60947-1
coil voltage415 V AC 50 Hz
Net weight4.6 kg
BrandSchneider
Brand SKULC1E200N5
ELINECK2FMK227
Sold asPer pc
RangeEasy TeSys
Height174 mm
StandardsEN/IEC 60947-1 · EN/IEC 60947-4-1 · GB/T 14048.1 · GB/T 14048.4
Motor power kW55 kW at 220/230 V AC 50/60 Hz · 90 kW at 380/400 V AC · 100 kW at 415/440 V AC · 110 kW at 500 V AC · 110 kW at 660/690 V AC · 110 kW at 660...690 V
Operating time20...35 ms on closing · 7...15 ms on opening
Fire resistance850 °C conforming to IEC 60695-2-1
Heat dissipation18…24 W for control circuit
Mounting supportPlate
Pollution degree3
Range of productEasy TeSys Control
Average impedance0.33 mOhm - Ith 250 A 50 Hz for power circuit
Device short nameLC1E
Poles description3P
Tightening torqueControl circuit: 1.2 N.m · Power circuit: 18 N.m
Inrush power in VA805 VA 50 Hz cos phi 0.3 (at 20 °C) · 970 VA 60 Hz cos phi 0.3 (at 20 °C)
Operating altitude3000 m without derating
Control circuit typeAC at 50 Hz
Overvoltage categoryIII
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Utilisation categoryAC-3 · AC-3e · AC-1
Contactor applicationMotor control · Resistive load
Electrical durability500000 cycles AC-3 · 200000 cycles AC-1
Mechanical durability5000000 cycles
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) · Vibrations contactor closed (3 Gn, 5...300 Hz) · Shocks contactor open (6 Gn for 11 ms) · Shocks contactor closed (7 Gn for 11 ms)
Associated fuse rating315 A gG at <= 690 V coordination type 1 for power circuit
Maximum operating rate1200 cyc/h 55 °C
Product certificationsCB Scheme · CCC · CE · EAC
Connections - terminalsPower circuit: cable with lug 1 1…4 mm² - external diameter: 150 mm - cable stiffness: flexible without cable end · Power circuit: bars 2 1…4 mm² - cable stiffness: flexible without cable end - busbar cross section: 3 x 25 mm · Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end · Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexibl
IP degree of protectionIP2X conforming to IEC 60529
Rated breaking capacity1600 A at 440 V for power circuit conforming to IEC 60947
Pole contact composition3 NO
Product or component typeContactor
Irms rated making capacity2000 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Power dissipation per pole13 W AC-3 · 21 W AC-1
[Uc] control circuit voltage415 V AC 50 Hz
Auxiliary contact compositionWithout
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50 Hz · 0.35...0.55 Uc (-5…55 °C):drop-out 50 Hz
[Ie] rated operational current200 A (at <55 °C) at <= 440 V AC AC-3 for power circuit · 175 A (at <55 °C) at <= 440 V AC AC-3e for power circuit · 250 A (at <40 °C) at <= 440 V AC AC-1 for power circuit
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
Hold-in power consumption in VA55 VA 50 Hz cos phi 0.3 (at 20 °C) · 66 VA 60 Hz cos phi 0.3 (at 20 °C)
[Uimp] rated impulse withstand voltage8 kV coil not connected to the power circuit conforming to IEC 60947
[Icw] rated short-time withstand current1500 A 40 °C - 10 s for power circuit
[Ith] conventional free air thermal current250 A (at 40 °C) for power circuit
Permissible ambient air temperature around the device-20…70 °C at Uc · -60…80 °C storage · -5…55 °C operation
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet