Schneider Schneider TeSys LP1K Power Contactor · 3P · 6 A AC-3 · 1 NO aux · 110 V DC coil · LP1K0610FD
Poles3P
Rated current6 A
Ingress protectionIP2X
Reference standardEN/IEC 60947-4-1
coil voltage110 V DC
Net weight0.225 kg
BrandSchneider
Brand SKULP1K0610FD
ELINE6H937RCD4
Sold asPer pc
Depth57 mm
RangeTeSys
Width45 mm
Height58 mm
StandardsEN/IEC 60947-4-1 · EN/IEC 60947-5-1 · UL 60947-4-1 · UL 60947-5-1 · CSA C22.2 No 60947-4-1 · CSA C22.2 No 60947-5-1 · GB/T 14048.4
Motor power kW1.5 kW at 220...230 V AC 50/60 Hz AC-3 · 2.2 kW at 380...415 V AC 50/60 Hz AC-3 · 3 kW at 440/690 V AC 50/60 Hz AC-3 · 1.5 kW at 220...230 V AC 50/60 Hz AC-3e · 2.2 kW at 380...415 V AC 50/60 Hz AC-3e · 3 kW at 440/690 V AC 50/60 Hz AC-3e · 1.5 kW at 220...230 V AC 50/60 Hz AC-4 · 2.2 kW at 380...415 V AC 50/60 Hz AC-4 · 3 kW at 440/690 V AC 50/60 Hz AC-4
Operating time30...40 ms coil energisation and NO closing · 10 ms coil de-energisation and NO opening
Coil technologyWithout built-in suppressor module
Heat dissipation1.3 W
Mounting supportRail · Plate
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Device short nameLP1K
Inrush power in W3 W (at 20 °C)
Poles description3P
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 2 · 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm · 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Control circuit typeDC standard
Overvoltage categoryIII
Utilisation categoryAC-3 · AC-3e · AC-4
Contactor applicationMotor control
Electrical durability1.3 Mcycles 6 A AC-3 at Ue <= 440 V · 1.3 Mcycles 6 A AC-3e at Ue <= 440 V · 0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Insulation resistance> 10 MOhm for signalling circuit
Mechanical durability10 Mcycles
Associated fuse rating25 A gG at <= 440 V for power circuit · 25 A aM for power circuit · 10 A gG for signalling circuit conforming to IEC 60947 · 10 A gG for signalling circuit conforming to VDE 0660
Maximum operating rate3600 cyc/h
Product certificationsCB Scheme · CCC · UL · CSA · EAC · CE · UKCA
Auxiliary contacts typetype instantaneous 1 NO
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid · Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end · Screw clamp terminals 2 cable(s) 1.5…4 mm²solid · Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end · Power circuit:
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947 · 110 A at 380...400 V conforming to IEC 60947 · 110 A at 415 V conforming to IEC 60947 · 110 A at 440 V conforming to IEC 60947 · 80 A at 500 V conforming to IEC 60947 · 70 A at 660...690 V conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 · B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Product or component typeContactor
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947 · 110 A AC for signalling circuit conforming to IEC 60947
[Uc] control circuit voltage110 V DC
Auxiliary contact composition1 NO
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508 · Power circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-5-1 · Signalling circuit: 600 V conforming to UL 508 · Power circuit: 600 V conforming to CSA C22.2 No 14 · Signalling circuit: 600 V conforming to CSA C22.2 No 14
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at = 0.10 Uc (at <50 °C)
Hold-in power consumption in W3 W at 20 °C
[Ie] rated operational current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit · 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz · Signalling circuit: <= 690 V AC <= 400 Hz
power pole contact composition3 NO
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit · 85 A 50 °C - 5 s for power circuit · 80 A 50 °C - 10 s for power circuit · 60 A 50 °C - 30 s for power circuit · 45 A 50 °C - 1 min for power circuit · 40 A 50 °C - 3 min for power circuit · 20 A 50 °C - >= 15 min for power circuit · 80 A - 1 s for signalling circuit · 90 A - 500 ms for signalling circuit · 110 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit · 10 A (at 50 °C) for signalling circuit
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.