Schneider Schneider TeSys LC2K Reversing Contactor · 3P · 16 A AC-3 · 1 NO aux · 230 V AC coil · LC2K1610P7
Poles3P
Rated current16 A
Ingress protectionIP20
Reference standardEN/IEC 60947-4-1
coil voltage230 V AC 50/60 Hz
Net weight0.39 kg
BrandSchneider
Brand SKULC2K1610P7
ELINE2CJGGRKPD
Sold asPer pc
RangeTeSys
StandardsEN/IEC 60947-4-1 · GB/T 14048.4 · UL 60947-4-1 · CSA C22.2 No 60947-4-1 · JIS C8201-4-1
Product nameTeSys K
Motor power kW4 kW at 220...230 V AC 50/60 Hz · 7.5 kW at 380...415 V AC 50/60 Hz · 5.5 kW at 440 V AC 50/60 Hz · 4 kW at 690 V AC 50/60 Hz
Operating time10...20 ms coil energisation and NO closing · 10...20 ms coil de-energisation and NO opening
Heat dissipation1.3 W
Mounting supportRail · Plate
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Device short nameLC2K
Interlocking typeMechanical
Poles description3P
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 2 · 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm · 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Device applicationControl
Inrush power in VA30 VA (at 20 °C)
Device presentationPreassembled with reversing power busbar
Control circuit typeAC at 50/60 Hz
Non overlap distance0.5 mm
Overvoltage categoryIII
Utilisation categoryAC-3 · AC-3e · AC-4
Contactor applicationMotor control
Electrical durability1.3 Mcycles 16 A AC-3 at Ue <= 440 V · 1.3 Mcycles 16 A AC-3e at Ue <= 440 V
Mechanical durability5 Mcycles
Associated fuse rating25 A gG at <= 440 V for power circuit · 25 A aM for power circuit · 10 A gG for signalling circuit conforming to IEC 60947 · 10 A gG for signalling circuit conforming to VDE 0660
Maximum operating rate3600 cyc/h
Product certificationsCB Scheme · CCC · UL · CSA · EAC · CE · UKCA
Auxiliary contacts typetype instantaneous 1 NO
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid · Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end · Screw clamp terminals 2 cable(s) 1.5…4 mm²solid · Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Rated breaking capacity110 A at 440 V conforming to IEC 60947 · 80 A at 500 V conforming to IEC 60947 · 70 A at 660...690 V conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 · B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Product or component typeReversing contactor
Irms rated making capacity160 A AC for power circuit conforming to IEC 60947 · 110 A AC for signalling circuit conforming to IEC 60947
Signalling circuit frequency<= 400 Hz
[Uc] control circuit voltage230 V AC 50/60 Hz
Auxiliary contact composition1 NO
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508 · Power circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-5-1 · Signalling circuit: 600 V conforming to UL 508 · Power circuit: 600 V conforming to CSA C22.2 No 14 · Signalling circuit: 600 V conforming to CSA C22.2 No 14
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at <50 °C) · Drop-out: 0.2...0.75 Uc (at <50 °C)
[Ie] rated operational current16 A (at <60 °C) at <= 440 V AC AC-3 for power circuit · 16 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Ue] rated operational voltagePower circuit: 690 V AC 50/60 Hz · Signalling circuit: <= 690 V AC 50/60 Hz
power pole contact composition3 NO
Hold-in power consumption in VA4.5 VA (at 20 °C)
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit · 105 A 50 °C - 5 s for power circuit · 100 A 50 °C - 10 s for power circuit · 75 A 50 °C - 30 s for power circuit · 55 A 50 °C - 1 min for power circuit · 50 A 50 °C - 3 min for power circuit · 25 A 50 °C - >= 15 min for power circuit · 80 A - 1 s for signalling circuit · 90 A - 500 ms for signalling circuit · 110 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit · 10 A (at 50 °C) for signalling circuit
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.