Elume House Wire · FR · 4 sq mm · 45 m · EclipseELM-FR-4-45-ECLIPSE↓ 48% off1 / 3
BrandElume
CategoryWires & Cables
SpecificationElume FR · 4 sq mm · single core · class-5 flexible copper (IS 8130) · 45 m coil · FR PVC, self-extinguishing · 1100 V · IS 694 · Eclipse (black)
Brand SKUELM-FR-4-45-ECLIPSE
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Elume· In stock
Visit the Elume store

Elume House Wire · FR · 4 sq mm · 45 m · Eclipse

Size: 4 sq mm
Colour: Eclipse
Length: 45 m
$56.28/coil-48%
$108.22
Wholesale · 15+ units
$53.47 /coil
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$56.28 /coil
Delivery in 8 to 15 business days
The house label

Wire, the way we believe it should be made.

Elume FR begins as bright annealed electrolytic copper, drawn to IS 8130 and stranded into a class-5 conductor that moves through conduit the way it should. It is insulated in a flame-retardant compound that refuses to carry fire, and finished in a palette you will recognise from across a site.

Then every single coil, not a sample, is spark-tested at high voltage before it is allowed into the box. The box, you will notice, was not an afterthought either.

Elume FR house wire carton
IS 694 · IS 8130
Made to the Indian standards for PVC-insulated cables and copper conductors, end to end.
Class-5 flexible copper
Bright annealed electrolytic copper, drawn fine and stranded for conduit work that flows instead of fights.
Self-extinguishing FR PVC
Insulation compounded to resist ignition and stop carrying a flame when the source is removed.
Oxygen index, ASTM D2863
Tested above the threshold of standard PVC. It takes more oxygen than air can offer to keep it burning.
Low smoke, ASTM D2843
In the minutes that matter, visibility is safety. The compound is tested for low smoke density.
Spark-tested. Every coil.
Each length passes a high-voltage spark test before it is boxed. Not a sample from the batch. All of it.
A palette of light
Seven finishes. The electrical colour is printed on every carton.
Ultraviolet
bright purple
Solar Flare
yellow
Aurora
green
Ember
red
Midnight
blue
Moonlight
white
Eclipse
black
The Elume promise

“Beyond the wire, we deliver the light that empowers families and the safety that protects them.”

RoHS compliant · lead-free · 1100 V grade · dispatched in a rigid printed carton, sized to shelve flat and stack clean.
IS 694IS 694ASTMASTMCECERoHSRoHSREACHREACH
Elume specification brochureElume brochure, brand and contact
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.
Product
Size
Coil length
Insulation
Cores
Voltage grade
Price
4 sq mm
45 m
FR
Single core
1100 V
$56.28 /coil
Viewing above ↑
4 sq mm
45 m
FR
Single core
1100 V
$59.13 /coil
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $53.47/coil on this product, applied automatically

Elume FR is a multi-stranded flexible copper wire built for the modern Indian home. Its FR PVC insulation handles overloads, resists moisture and self-extinguishes, protecting the family on the other side of the wall, not just the circuit. Every metre is spark-tested and conductivity-verified before it leaves our facility.

  • 99.9% pure electrolytic grade copper, drawn, annealed and bunched
  • Self-extinguishing FR PVC insulation with high insulation resistance
  • Every metre spark-tested and conductivity-verified
  • 'elume' printed along the full length for easy identification
  • IS 694 certified; RoHS and REACH compliant
Pure copper, no compromise
Built from 99.9% pure electrolytic grade copper, drawn, annealed and bunched for maximum flexibility, conductivity and long life.
FR insulation that stands guard
A precisely formulated FR PVC compound, extruded on precision high-speed lines for consistent thickness across every metre. It handles overloads safely and resists boiling water, steam and moisture.
Tested beyond the standard
Oxygen Index and Smoke Density tested generally conforming to ASTM D2863 and D2843, with results that outperform standard PVC cables.
Spark-tested. Every coil.
Every coil is spark-tested and conductivity-verified before it leaves the facility. That is not a policy, it is a promise.
As published by Elume. Verify critical parameters against the datasheet before specifying.

Technical data · Elume FR

Conductor99.9% bright annealed electrolytic copper (IS 8130) · class 5
Strand construction56/0.3 (no./mm)
InsulationFR PVC, flame retardant, self-extinguishing
Insulation thickness0.8 mm
Overall diameter4.8 mm
Current-carrying capacity26–29 A
Max conductor resistance4.95 Ω/km at 20°C
Voltage grade1100 V
StandardsIS 694, IS 8130, RoHS, REACH, CE (generally conforming)
Packing45 m coil, rigid printed carton

Fire & safety test results

TestMethodSpecified value
Critical Oxygen IndexASTM D2863Above standard PVC
Smoke DensityASTM D2843Low smoke
High-voltage spark testEvery batch100% of production
Available colours: Ultraviolet, Solar Flare, Aurora, Ember, Midnight, Moonlight, Eclipse
Elume Elume House Wire · FR · 4 sq mm · 45 m · Eclipse · ELM-FR-4-45-ECLIPSE
Conductor size4 sq mm
CoresSingle core
ConductorElectrolytic copper
Voltage grade1100 V
Length45 m
ColourEclipse
Coil length45 m
Core colourEclipse
Reference standardIS 694:2010
ApplicationFixed internal wiring - conduit & casing-capping
BrandElume
Brand SKUELM-FR-4-45-ECLIPSE
ELINELUME00135
Sold asPer coil
Ratings as published by Elume (Product name; Elume catalogue). Verify critical parameters against the datasheet before specifying.
Effective price
$1.25/m
Wholesale (15+ coils)
$1.19/m
List price equivalent
$2.40/m
Read: Importing Electrical Goods for a Project: Incoterms, Documents and Lead Times Explained →
What is the difference between FOB and CIF?
Under FOB the seller's job ends when the goods are loaded on the vessel at the origin port; you pay the freight and insurance. Under CIF the seller also pays the freight and minimum insurance to your destination port, but the risk still passes to you at loading.
Which Incoterm should I use for courier shipments?
DAP is the usual choice: the seller delivers to your door and you clear import duties. FCA or CPT also work if you prefer to arrange or control the carriage yourself.
Do I need a certificate of origin?
You need it to claim preferential duty under a trade agreement, and some importing countries ask for it on every shipment. Ask for it with the quote so it is issued before dispatch.
FR vs FRLS vs HFFR / ZHFR - which wire should I buy for my home?

FR (flame retardant) slows the spread of fire; FRLS also gives off much less smoke; HFFR / ZHFR (halogen free) additionally avoids toxic, corrosive halogen gases when it burns. FRLS is a sensible minimum for homes, and halogen-free wire is worth it for bedrooms, escape routes and enclosed spaces if the budget allows.

Which wire size should I use for lights, sockets, AC and geyser?

Common practice in Indian homes is 1.5 sq mm for lights and fans, 2.5 sq mm for 6A/16A socket circuits, 4 sq mm on a dedicated circuit for a 1.5 ton AC or geyser, and 6 sq mm or more for the main supply to the distribution board. Long runs and higher loads need a bigger size, so have a licensed electrician confirm sizes against the MCB ratings.

What size is this wire and what is it suitable for?

The listed size of this wire is 4 sq mm. As a rule of thumb, 1-1.5 sq mm suits lighting, 2.5 sq mm suits socket circuits, 4 sq mm suits AC or geyser circuits and 6 sq mm and above suits mains and sub-mains; always match the wire to the MCB rating and have a licensed electrician confirm.

How can I check the length of a wire coil?

The declared length is printed on the pack, and many brands also print running metre marks on the insulation, so you can compare the start and end readings.

How do I check the wire is genuine and ISI marked?

Look for the ISI mark with a CM/L licence number printed on the wire and the pack. You can verify the licence number on the BIS Care app; PVC-insulated house wires are made to IS 694.

Which colour wire should be used for phase, neutral and earth?

In Indian fixed wiring, red is used for phase (with yellow and blue for the other phases on three-phase supply), black for neutral and green or green-yellow for earth. Sticking to these colours makes future maintenance safer and is what electricians expect.

Is copper wire better than aluminium for house wiring?

Yes, copper is the standard for internal house wiring because it carries more current for the same size, is more flexible and makes more reliable joints. Aluminium is mainly used for larger supply and armoured cables.

Does a higher temperature rating (HR, 85 or 105 deg C) matter?

Standard PVC wire is rated for 70 deg C conductor temperature, while heat-resistant grades handle higher temperatures and age more slowly under heavy, continuous loads. It is useful for kitchens, AC and geyser circuits and hot roof slabs, but it does not replace choosing the correct wire size.

No reviews yet