🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider Harmony Control Relay · 3-phase · Phase loss sequence asymmetry and over/undervoltage · 208-480 V AC · RM10TE00NRM10TE00N↓ 40% off1 / 11
BrandSchneider
CategoryIndustrial Control
SpecificationHarmony 3 phase voltage monitoring relay, Range 208 to 480 VAC, phase sequence, phase failure, Phase imbalance, 1 CO
Brand SKURM10TE00N
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Harmony Control Relay · 3-phase · Phase loss sequence asymmetry and over/undervoltage · 208-480 V AC · RM10TE00N

$29.12/pc-40%
$48.54
Wholesale · 15+ units
$27.67 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$29.12 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $27.67/pc on this product, applied automatically

This monitoring relay relay belongs to Schneider Electric's Easy Harmony Control relays range. It allows monitoring of power supply circuits in 3-phase networks. This enhanced version relay monitors phase loss, phase sequence, phase asymmetry, and over and underr voltage. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail. This product comes with simple rotary dial setting for intended 3 phase monitoring control function. The product monitors its own power supply, when the power supply is abnormal, the output relay de-energizes. Its dimensions are 17.5mm (width) x 58.5mm (height) x 90mm (depth) and weighs 0.075 kg. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, HVAC compressor, pump and fan motor related monitoring and control. It conforms to international standard, certifications and markings cULus, CE, CCC, and UKCA.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Harmony Control Relay · 3-phase · Phase loss sequence asymmetry and over/undervoltage · 208-480 V AC · RM10TE00N · RM10TE00N
Ingress protectionIP20 (terminals)
Reference standardIEC 60255-1
Net weight0.075 kg
BrandSchneider
Brand SKURM10TE00N
ELINEKRP3GHP6C
Sold asPer pc
Depth58.5 mm · 58.4 mm
Width17.5 mm · 17.8 mm
Height90 mm · 88.9 mm
MarkingCULus · CE · UKCA · CCC
Function3-phase phase loss sequence asymmetry and over/undervoltage
StandardsIEC 60255-1
Hysteresis2 %
Relay nameRM10TE
Relay typeControl relay
Reset time1.5 s time delay
Response time< 550 ms (in the event of a fault)
Measuring range208-480 V AC
Output contacts1 C/O
Time delay typeAdjustable 0...100 s, +/- 10 % of the full scale value
Housing materialPolycarbonate
Local signallingLED (green) for ST (status) · LED (red) for overvoltage · LED (red) for undervoltage · LED (red) for alarm asymmentry failure triggered
Mounting support35 mm symmetrical DIN rail conforming to IEC 60715
Pollution degree2
Range of productHarmony Control Relays
Reliability dataMTTFd = 158 years
Supply frequency47...63 Hz
Measurement error< 0.05 %/°C with temperature variation · < 1 % over the whole range with voltage variation
Measurement range208...480 V AC
Relative humidity10…95 %
Tightening torque0.5…0.7 N.m
Overvoltage categoryII
Electrical durability100000 cycles
Insulation resistance> 100 MOhm at 500 V DC
Mechanical durability10000000 cycles
Supply voltage limits183…528 V AC, 3 phases
Product certificationscULus · CE · UKCA · CCC
nominal output current5 A
Connections - terminalsScrew terminals, 2 x 0.5...2 x 1.5 mm² (20 AWG...16 AWG) solid with or without cable end
Dielectric test voltage1.89 kV, 1 min AC 50 Hz
IP degree of protectionIP20 (terminals) · IP40 (casing)
Power consumption in VA0…4.5 VA
Switching capacity in VA1250 VA
Product or component type3-phase control relay
Relay monitored parametersPhase sequence · Phase failure detection · Asymmetry · Overvoltage and undervoltage detection
Voltage detection threshold< 175 V AC
Product specific applicationFor 3-phase supply
Electromagnetic compatibilityconforming to IEC 61000-6-4 · conforming to IEC 61000-6-3 · conforming to IEC 61000-6-2
[Ui] rated insulation voltage400 V
Setting accuracy of time delay10 %
Ambient air temperature for storage-40…70 °C · -40…70 °C
Ambient air temperature for operation-15…60 °C
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
What is the difference between on-delay and off-delay timers?

An on-delay timer switches its output after the set time once it receives power or a start signal, while an off-delay timer holds its output on for the set time after the signal is removed. Multifunction timers offer both and other modes such as cyclic and interval.

Which timer do I need for a star-delta starter?

A dedicated star-delta timer has a built-in short dead time between star and delta changeover to prevent a short circuit across contactors. The star time is set to suit how fast the motor reaches near full speed, often a few seconds to around 15 seconds.

What does a phase failure relay protect against?

A phase monitoring relay detects phase loss, phase reversal (wrong sequence) and often phase unbalance or under/over voltage, and trips the contactor coil to protect three-phase motors. It is especially useful for pumps, compressors and lifts where wrong rotation or single phasing can cause damage.

Can I use a timer to run a water pump automatically?

A cyclic or programmable timer can switch a pump contactor on and off at set intervals, but for tank level control a level controller relay with probes or a float switch is more reliable. The pump also needs proper motor protection like an MPCB or overload relay.

Do these mount on DIN rail?

Most modern timers and monitoring relays are DIN rail mounted (35mm), while some older or plug-in types use an 8-pin or 11-pin socket base. Check the mounting type and whether the base is included.

No reviews yet