Schneider Linergy GV1G Terminal Block · TeSys GV2 · TeSys D & TeSys U · 3P · from the top · GV1G09GV1G09↓ 40% off
BrandSchneider
CategoryIndustrial Control
SpecificationTeSys GV2 · TeSys D & TeSys U · 3P · from the top
Brand SKUGV1G09
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Linergy GV1G Terminal Block · TeSys GV2 · TeSys D & TeSys U · 3P · from the top · GV1G09

$41.78/pc-40%
$69.64
Wholesale · 15+ units
$39.69 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$41.78 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $39.69/pc on this product, applied automatically

TeSys GV terminal block, 3 phases, 63A/690V, to supply busbar sets GV2G. To be inserted directly on the top terminals of the devices connected by the busbar sets. Connection to the supply cable by screw connectors. Green Premium compliant (RoHS/REACh).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Linergy GV1G Terminal Block · TeSys GV2 · TeSys D & TeSys U · 3P · from the top · GV1G09 · GV1G09
Poles3P (TP)
Rated current63 A
Ingress protectionIP20
Net weight0.04 kg
BrandSchneider
Brand SKUGV1G09
ELINEJ6M7H6MHF
Sold asPer pc
RangeLinergy
Product nameFT
Device short nameGV1G
Mounting locationTop
Poles description3P
Tightening torque1.7 N.m - on screw clamp terminals · 2.2 N.m - on connector
Range compatibilityTeSys GV2 · TeSys Deca · TeSys U · TeSys LS1
Product certificationsCE · UKCA
Connections - terminalsScrew clamp terminals 1 cable(s) (4 AWG) - solid · Screw clamp terminals 1 cable(s) 1.5…16 mm² - flexible with cable end · Screw clamp terminals 1 cable(s) 1.5…16 mm² - flexible without cable end · Screw clamp terminals 1 cable(s) 1.5…25 mm² - solid · Screw clamp terminals 2 cable(s) 1.5…4 mm² - flexible with cable end · Screw clamp terminals 2 cable(s) 1.5…6 mm² - solid · Screw clamp terminals 2
IP degree of protectionIP20 conforming to IEC 60529
Product or component typeTerminal block
[Ui] rated insulation voltage690 V conforming to IEC 60947-1
[Ie] rated operational current63 A
Accessory / separate part categoryConnection accessory
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
What is the difference between MPCB and MCB for a motor?

An MPCB has an adjustable overload setting matched to the motor's current and a magnetic trip set to handle motor starting current, plus phase loss sensitivity. An MCB has fixed overload settings meant for cables, so it does not protect a motor as precisely (MPCBs are covered by IS/IEC 60947-2 and 60947-4-1).

Can an MPCB replace an overload relay and fuses?

Yes, an MPCB gives short-circuit and overload protection plus isolation in one device, so with a contactor it forms a compact DOL starter without a separate overload relay or fuses. Check the manufacturer's coordination table for the right contactor pairing.

Can I start and stop the motor directly with the MPCB?

Yes, an MPCB can be used as a manual motor starter for occasional on/off switching. For frequent starts, remote control or float/pressure switch operation, pair it with a contactor.

Which accessories are available for an MPCB?

Common accessories include auxiliary contacts, trip-indication contacts, undervoltage and shunt releases, enclosures for wall mounting and connection links to contactors. These are usually specific to the MPCB range.

My MPCB trips when the motor starts - what should I check?

Check that the dial is set to the motor's full-load current, that all three phases are present and balanced, and that the pump or load is not jammed. If the motor current is near the top of the range, the next range up may be needed; consult an electrician before increasing settings.