🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider Zelio Logic Modular Smart Relay · 24 I O · 24 V AC · clock · display · SR3B261BSR3B261B↓ 40% off1 / 6
BrandSchneider
CategoryIndustrial Control
Specification24 I O · 24 V AC · clock · display
Brand SKUSR3B261B
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Zelio Logic Modular Smart Relay · 24 I O · 24 V AC · clock · display · SR3B261B

$566.91/pc-40%
$944.85
Wholesale · 15+ units
$538.57 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$566.91 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $538.57/pc on this product, applied automatically

This product is part of the Zelio Logic range, an offer of smart relays for simple automation systems from 10 to 40 I/Os. The compact smart relay provides a real alternative to solutions based on cabled logic or specific cards. It comes with display and clock. Checks program memory on each power up and 0 to 240 with ladder programming number or control scheme lines. Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards It offers 10 relay outputs with normally opened contact and 16 discrete inputs. It is a smart relay with a rated supply voltage of 24V, a maximum supply current of 280mA (without extension) and a power consumption of 7.5VA without extension. It is an IP20 and IP40 rated product. It weighs 0.4kg. This product meets EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 60068-2-6 Fc, EN/IEC 60068-2-27 Ea, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-3 and EN/IEC 61000-4-12 standards. Simple to select, install and program, Zelio Logic is suitable for all your applications. Flexible, it offers you the choice of 2 ranges, compact or modular, extendable and 2 programming languages (FBD

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Zelio Logic Modular Smart Relay · 24 I O · 24 V AC · clock · display · SR3B261B · SR3B261B
Ingress protectionIP20 (terminal block)· IP40 (front panel)
Reference standardIEC 61000-4-5
Net weight0.4 kg
BrandSchneider
Brand SKUSR3B261B
ELINEHRHJ2CGDF
Sold asPer pc
ClockWith
ChecksProgram memory on each power up
StandardsIEC 61000-4-5 · IEC 61000-4-11 · IEC 61000-4-2 level 3 · IEC 61000-4-6 level 3 · IEC 60068-2-6 Fc · IEC 60068-2-27 Ea · IEC 61000-4-4 level 3 · IEC 61000-4-3 · IEC 61000-4-12
Cycle time6…90 ms
Backup time10 years at 25 °C
Clock drift12 min/year at 0…55 °C · 6 s/month at 25 °C
Local displayWith
Response time50 ms with ladder programming (from state 0 to state 1) for discrete input · 50 ms with ladder programming (from state 1 to state 0) for discrete input · 50...255 ms with FBD programming (from state 0 to state 1) for discrete input · 50...255 ms with FBD programming (from state 1 to state 0) for discrete input · 10 ms (from state 0 to state 1) for relay output · 5 ms (from state 1 to state 0) for
Input impedance4.6 kOhm for discrete input
Protection typeAgainst inversion of terminals (control instructions not executed)
Range of productZelio Logic
Supply frequency50/60 Hz
Isolation voltage1780 V
Number of outputs10 relay
Tightening torque0.5 N.m
Operating rate in Hz0.1 Hz (at Ie) for relay output · 10 Hz (no load) for relay output
Overvoltage categoryIII conforming to IEC 60664-1
Discrete input number16
Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to IEC 60947-5-1 · AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to IEC 60947-5-1 · DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to IEC 60947-5-1 · DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to IEC 60947-5-1
Mechanical durability10000000 cycles for relay output
Output voltage limits5...30 V DC (relay output) · 24...250 V AC
Supply voltage limits20.4…28.8 V
Discrete input current4.4 mA
Discrete input voltage24 V AC
Maximum supply current280 mA (without extension) · 415 mA (with extensions)
Output thermal current5 A for 2 outputs for relay output · 8 A for 8 outputs for relay output
Product certificationsGOST · GL · UL · CSA · C-Tick
Connections - terminalsScrew terminals, 1 x 0.2...1 x 2.5 mm² (25 AWG...14 AWG) semi-solid · Screw terminals, 1 x 0.2...1 x 2.5 mm² (25 AWG...14 AWG) solid · Screw terminals, 1 x 0.25...1 x 2.5 mm² (24 AWG...14 AWG) flexible with cable end · Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) solid · Screw terminals, 2 x 0.25...2 x 0.75 mm² (24 AWG...18 AWG) flexible with cable end
IP degree of protectionIP20 (terminal block) conforming to IEC 60529 · IP40 (front panel) conforming to IEC 60529
Immunity to microbreaks10 ms repeated 20 times
Power consumption in VA10 VA with extensions · 7.5 VA without extension
Discrete input frequency47...53 Hz · 57...63 Hz
Switching capacity in mA>= 10 mA at 12 V (relay output)
Product or component typeModular smart relay
[Us] rated supply voltage24 V
Current state 0 guaranteed<= 0.5 mA (discrete input)
Current state 1 guaranteed>= 2 mA (discrete input)
Voltage state 0 guaranteed<= 5 V for discrete input
Voltage state 1 guaranteed>= 14 V for discrete input
Environmental characteristicEMC directive conforming to IEC 61000-6-2 · EMC directive conforming to IEC 61000-6-3 · EMC directive conforming to IEC 61000-6-4 · EMC directive conforming to IEC 61131-2 zone B · Low voltage directive conforming to IEC 61131-2
Contacts type and compositionNO for relay output
Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
Number or control scheme lines0…500 with FBD programming · 0…240 with ladder programming
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
What is the difference between on-delay and off-delay timers?

An on-delay timer switches its output after the set time once it receives power or a start signal, while an off-delay timer holds its output on for the set time after the signal is removed. Multifunction timers offer both and other modes such as cyclic and interval.

Which timer do I need for a star-delta starter?

A dedicated star-delta timer has a built-in short dead time between star and delta changeover to prevent a short circuit across contactors. The star time is set to suit how fast the motor reaches near full speed, often a few seconds to around 15 seconds.

What does a phase failure relay protect against?

A phase monitoring relay detects phase loss, phase reversal (wrong sequence) and often phase unbalance or under/over voltage, and trips the contactor coil to protect three-phase motors. It is especially useful for pumps, compressors and lifts where wrong rotation or single phasing can cause damage.

Can I use a timer to run a water pump automatically?

A cyclic or programmable timer can switch a pump contactor on and off at set intervals, but for tank level control a level controller relay with probes or a float switch is more reliable. The pump also needs proper motor protection like an MPCB or overload relay.

Do these mount on DIN rail?

Most modern timers and monitoring relays are DIN rail mounted (35mm), while some older or plug-in types use an 8-pin or 11-pin socket base. Check the mounting type and whether the base is included.

No reviews yet