Schneider Schneider Harmony XB2 Complete Body/Contact Assembly · body for control button · Ø 22 mm · 30 mm · 1 NO · ZB2BZ101C · ZB2BZ101C
Rated current3 A
Reference standardIEC 60947-1
Net weight0.04 kg
BrandSchneider
Brand SKUZB2BZ101C
ELINEGP7P2KFF7
Sold asPer pc
Depth42.5 mm
Width30 mm
Height40 mm
Contacts1 NO
Body typeBody for control button
Fixing modeFixing screw beneath head recommended torque: 0.8 N.m · Fixing screw beneath head recommended torque: 1.0 N.m
CustomizableNo
Light sourceWithout
Bezel materialChromium plated metal
Component nameZB2
Contacts usageStandard contacts
Operating travel2.38 mm (NO changing electrical state) · 5 mm (total travel)
Positive openingWithout
Range of productHarmony XB2
Contact operationSlow-break
Contacts materialSilver alloy (Ag/Ni)
Device short nameXB2
Mounting diameter22.5 mm
Tightening torque0.8…1.0 N.m
Light block colourNone
Light block supplyWithout supply
Device presentationBasic sub-assemblies
Shape of screw headCross compatible with Philips no 1 screwdriver · Cross compatible with pozidriv No 1 screwdriver · Slotted compatible with flat Ø 4 mm screwdriver · Slotted compatible with flat Ø 5.5 mm screwdriver
Protective treatmentTC/TH
Electrical connectionCaptive screw clamp terminal
Electrical durability1000000 cycles, AC-15, 3 A at 240 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C · 1000000 cycles, DC-13, 0.27 A at 250 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability3000000 cycles
NC auxiliary contacts1
NO auxiliary contacts0
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4 · Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4
Fixing collar materialZamak
Connections - terminalsScrew clamps terminals
Contact code designationA600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 947-5-1 appendix A · A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 947-5-1 appendix A · Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 947-5-1 appendix A · Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 947-5-1 appendix A
Short-circuit protection10 A gL fuse type gG conforming to IEC 60947-5-1
Product or component typeComplete body/contact assembly
Rated operational power in W40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 conforming to IEC 60947-5-1 · 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 conforming to IEC 60947-5-1 · 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 conforming to IEC 60947-5-1
Contacts type and composition1 NO
Sale per indivisible quantity1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
Terminals description ISO n°1(13-14)NO
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 · 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1
[Ie] rated operational current AC3 A 240 V AC-15
[Ie] rated operational current DCDC-13: 0.27 A at 250 V
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.