🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider TeSys LC1K Power Contactor · 3P · 6 A AC-3 · 1 NO aux · 230-240 V AC coil · LC1K0610U7LC1K0610U7↓ 40% off1 / 4
BrandSchneider
CategoryIndustrial Control
Specification3P · 6 A AC-3 · 1 NO aux · 230...240 V AC coil
Brand SKULC1K0610U7
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider TeSys LC1K Power Contactor · 3P · 6 A AC-3 · 1 NO aux · 230-240 V AC coil · LC1K0610U7

Rating: 6 A AC-3
Coil: 230...240 V AC coil
$28.07/pc-40%
$46.76
Wholesale · 15+ units
$26.66 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$28.07 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $26.66/pc on this product, applied automatically

TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides a 230-240V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider TeSys LC1K Power Contactor · 3P · 6 A AC-3 · 1 NO aux · 230-240 V AC coil · LC1K0610U7 · LC1K0610U7
Poles3P (TP)
Rated current6 A
Ingress protectionIP2X
Reference standardEN/IEC 60947-4-1
coil voltage230...240 V AC 50/60 Hz
Net weight0.18 kg
BrandSchneider
Brand SKULC1K0610U7
ELINED9MMHJ24M
Sold asPer pc
RangeTeSys
Width45 mm
Height58 mm
Motor power kW1.5 kW at 220...230 V AC 50/60 Hz AC-3 · 2.2 kW at 380...415 V AC 50/60 Hz AC-3 · 3 kW at 440/690 V AC 50/60 Hz AC-3 · 1.5 kW at 220...230 V AC 50/60 Hz AC-3e · 2.2 kW at 380...415 V AC 50/60 Hz AC-3e · 3 kW at 440/690 V AC 50/60 Hz AC-3e · 1.5 kW at 220...230 V AC 50/60 Hz AC-4 · 2.2 kW at 380...415 V AC 50/60 Hz AC-4 · 3 kW at 440/690 V AC 50/60 Hz AC-4
Operating time10...20 ms coil de-energisation and NO opening · 10...20 ms coil energisation and NO closing
Coil technologyWithout built-in suppressor module
Heat dissipation1.3 W
Mounting supportRail · Plate
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Device short nameLC1K
Poles description3P
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 2 · 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm · 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Device applicationControl
Inrush power in VA30 VA (at 20 °C)
Control circuit typeAC at 50/60 Hz
Non overlap distance0.5 mm
Overvoltage categoryIII
Utilisation categoryAC-3 · AC-3e · AC-4
Contactor applicationMotor control
Electrical durability1.3 Mcycles 6 A AC-3 at Ue <= 440 V · 1.3 Mcycles 6 A AC-3e at Ue <= 440 V · 0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Insulation resistance> 10 MOhm for signalling circuit
Mechanical durability10 Mcycles
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC
Associated fuse rating25 A gG at <= 440 V for power circuit · 25 A aM for power circuit · 10 A gG for signalling circuit conforming to IEC 60947 · 10 A gG for signalling circuit conforming to VDE 0660
Maximum operating rate3600 cyc/h
Auxiliary contacts typetype instantaneous 1 NO
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid · Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end · Screw clamp terminals 2 cable(s) 1.5…4 mm²solid · Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947 · 110 A at 380...400 V conforming to IEC 60947 · 110 A at 415 V conforming to IEC 60947 · 110 A at 440 V conforming to IEC 60947 · 80 A at 500 V conforming to IEC 60947 · 70 A at 660...690 V conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 · B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Product or component typeContactor
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947 · 110 A AC for signalling circuit conforming to IEC 60947
Signalling circuit frequency<= 400 Hz
[Uc] control circuit voltage230...240 V AC 50/60 Hz
Auxiliary contact composition1 NO
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508 · Power circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-5-1 · Signalling circuit: 600 V conforming to UL 508 · Power circuit: 600 V conforming to CSA C22.2 No 14 · Signalling circuit: 600 V conforming to CSA C22.2 No 14
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C)
[Ie] rated operational current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit · 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz · Signalling circuit: <= 690 V AC <= 400 Hz
power pole contact composition3 NO
Hold-in power consumption in VA4.5 VA (at 20 °C)
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit · 85 A 50 °C - 5 s for power circuit · 80 A 50 °C - 10 s for power circuit · 60 A 50 °C - 30 s for power circuit · 45 A 50 °C - 1 min for power circuit · 40 A 50 °C - 3 min for power circuit · 20 A 50 °C - >= 15 min for power circuit · 80 A - 1 s for signalling circuit · 90 A - 500 ms for signalling circuit · 110 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit · 10 A (at 50 °C) for signalling circuit
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet