Rajdhani Cables has manufactured wires and cables in Delhi since 1972. An ISO 9001:2015 certified company, its building wires are made from bright annealed bare electrolytic copper to IS:8130 with dielectric-grade PVC insulation to IS:5831, and carry the ISI mark under IS:694.
Every strand is bunched into a circular unilay lay, so the conductor stays round, packs more copper into the same size and pulls through conduit without snagging.
Flame-retardant PVC insulation rated for 105°C hotspots resists spreading fire along the wire run.
Coils are cut to the marked length and the conductor to the marked size - the ISI mark under IS:694 is licensed and audited.
Rajdhani Submersible Unify Cable 3 Core Flat 2.5 sq mm · XLPE · 500 m Drum is a wire from Rajdhani. It carries power in fixed wiring; the size and insulation grade decide the current it can carry and how it behaves in a fire. Key ratings: Conductor size 2.5 sq mm, Cores 3 core, Conductor Electrolytic copper, Voltage grade 1100 V, Length 500 m.
It depends on the motor's HP and current, the supply voltage and the total cable length from the starter to the pump. As a rough guide, 1-1.5 HP single-phase pumps at moderate depths often use 1.5-2.5 sq mm, and deeper or bigger pumps need larger sizes; follow the pump maker's cable chart to avoid voltage drop and motor burnout.
Add the pump setting depth, the distance from the borewell to the starter or control panel, and a few extra metres for joints and slack. Buying slightly more is better than making extra joints.
Flat 3 core cable is the most common choice for borewells because it fits easily beside the pipe in narrow casings. Round cable is sturdier mechanically and is used where there is enough space, such as open wells or larger bores.
Yes, but the joint will be under water, so it must be made with a proper waterproof joint kit (heat-shrink or resin type) by an experienced electrician. A poorly sealed joint is the most common cause of earth leakage and motor tripping.
Flat and round submersible cables in India are made to IS 694, usually rated 1100 V with copper conductors. Check for the ISI mark and the licence number on the sheath.
Submersible cable is designed for continuous immersion in water when used within its rated temperature and voltage. Avoid sharp edges in the casing and do not let the cable carry the weight of the pump - use a safety rope.
The listed length of this cable is 500 m. Make sure that covers the pump depth plus the run to the starter and some spare for the joint.