🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Havells Life Shield HFFR 6.0 sq mm Cables · Black · WHFFZNKL16X07WHFFZNKL16X07↓ 3% off1 / 2
BrandHavells
CategoryWires & Cables
Specification6 sq mm
Brand SKUWHFFZNKL16X07
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Havells· In stock
Visit the Havells store

Havells Life Shield HFFR 6.0 sq mm Cables · Black · WHFFZNKL16X07

Colour: Black
$667.33/pc-3%
$690.93
Wholesale · 15+ units
$633.97 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$667.33 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $633.97/pc on this product, applied automatically

Havells Life Shield HFFR 6.0 sq mm Cables is an electrical product from Havells. Key ratings: conductor size 6 sq mm. This listing is the Black variant.

  • In Closed Confined Space Application: Flexible Cables for Internal electrification and power Supply to all electrical operated equipments (eg. Fans/Lights/ Aplliances etc).
  • Size: 0.50 sq. mm to 6.00 sq. mm in Single core
As published by Havells. Verify critical parameters against the datasheet before specifying.
Havells Havells Life Shield HFFR 6.0 sq mm Cables · Black · WHFFZNKL16X07 · WHFFZNKL16X07
Conductor size6 sq mm
ColourBlack
Core colourBlack
Reference standardIS 694:2010
ApplicationFixed internal wiring - conduit & casing-capping
BrandHavells
Brand SKUWHFFZNKL16X07
ELINEC7799D3HJ
Sold asPer pc
CoreSingle Core
Size6.0 sq. mm
ColorBlue
Ratings as published by Havells (havells.com). Verify critical parameters against the datasheet before specifying.
Read: Importing Electrical Goods for a Project: Incoterms, Documents and Lead Times Explained →
What is the difference between FOB and CIF?
Under FOB the seller's job ends when the goods are loaded on the vessel at the origin port; you pay the freight and insurance. Under CIF the seller also pays the freight and minimum insurance to your destination port, but the risk still passes to you at loading.
Which Incoterm should I use for courier shipments?
DAP is the usual choice: the seller delivers to your door and you clear import duties. FCA or CPT also work if you prefer to arrange or control the carriage yourself.
Do I need a certificate of origin?
You need it to claim preferential duty under a trade agreement, and some importing countries ask for it on every shipment. Ask for it with the quote so it is issued before dispatch.
FR vs FRLS vs HFFR / ZHFR - which wire should I buy for my home?

FR (flame retardant) slows the spread of fire; FRLS also gives off much less smoke; HFFR / ZHFR (halogen free) additionally avoids toxic, corrosive halogen gases when it burns. FRLS is a sensible minimum for homes, and halogen-free wire is worth it for bedrooms, escape routes and enclosed spaces if the budget allows.

Which wire size should I use for lights, sockets, AC and geyser?

Common practice in Indian homes is 1.5 sq mm for lights and fans, 2.5 sq mm for 6A/16A socket circuits, 4 sq mm on a dedicated circuit for a 1.5 ton AC or geyser, and 6 sq mm or more for the main supply to the distribution board. Long runs and higher loads need a bigger size, so have a licensed electrician confirm sizes against the MCB ratings.

How can I check the length of a wire coil?

The declared length is printed on the pack, and many brands also print running metre marks on the insulation, so you can compare the start and end readings.

How do I check the wire is genuine and ISI marked?

Look for the ISI mark with a CM/L licence number printed on the wire and the pack. You can verify the licence number on the BIS Care app; PVC-insulated house wires are made to IS 694.

Which colour wire should be used for phase, neutral and earth?

In Indian fixed wiring, red is used for phase (with yellow and blue for the other phases on three-phase supply), black for neutral and green or green-yellow for earth. Sticking to these colours makes future maintenance safer and is what electricians expect.

Is copper wire better than aluminium for house wiring?

Yes, copper is the standard for internal house wiring because it carries more current for the same size, is more flexible and makes more reliable joints. Aluminium is mainly used for larger supply and armoured cables.

Does a higher temperature rating (HR, 85 or 105 deg C) matter?

Standard PVC wire is rated for 70 deg C conductor temperature, while heat-resistant grades handle higher temperatures and age more slowly under heavy, continuous loads. It is useful for kitchens, AC and geyser circuits and hot roof slabs, but it does not replace choosing the correct wire size.