Schneider Harmony Control Relay · 3-phase · Phase loss and sequence · 183-528 V AC · RM10TG00RM10TG00↓ 40% off
BrandSchneider
CategoryIndustrial Control
SpecificationModular measurement and relay, Harmony relay, for 3-phase supply, without time delay, 183...528V AC, 1 C/O
Brand SKURM10TG00
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Harmony Control Relay · 3-phase · Phase loss and sequence · 183-528 V AC · RM10TG00

$42.07/pc-40%
$70.12
Wholesale · 15+ units
$39.97 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$42.07 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $39.97/pc on this product, applied automatically

Schneider Harmony Control Relay · RM10TG00 from Schneider Electric.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Harmony Control Relay · 3-phase · Phase loss and sequence · 183-528 V AC · RM10TG00 · RM10TG00
Ingress protectionIP20 (terminals)· IP30 (casing)
Reference standardEN/IEC 60255-1
Net weight0.085 kg
BrandSchneider
Brand SKURM10TG00
ELINE7PDR3PKG7
Sold asPer pc
Depth72 mm
Width17.5 mm
Height90 mm
MarkingCE
Function3-phase phase loss and sequence
StandardsEN/IEC 60255-1
Directives89/336/EEC - electromagnetic compatibility · 73/23/EEC - low voltage directive
Relay nameRM10TG
Relay typeControl relay
Response time<= 130 ms (in the event of a fault)
Measuring range183-528 V AC
Output contacts1 C/O
Time delay typeWithout
Housing materialPolycarbonate
Local signallingLED (yellow) for relay ON
Mounting support35 mm symmetrical DIN rail conforming to EN/IEC 60715
Pollution degree3 conforming to IEC 60664-1
Range of productHarmony Relay
Reliability dataB10d = 850000 · MTTFd = 924.6 years
Supply frequency50/60 Hz +/- 10 %
Relative humidity95 % at 55 °C conforming to IEC 60068-2-30
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Operating positionAny position without derating
Overvoltage categoryIII conforming to IEC 60664-1
Electrical durability100000 cycles
Insulation resistance> 500 MOhm at 500 V DC conforming to IEC 60255-5
Mechanical durability30000000 cycles
Supply voltage limits183…528 V AC
Product certificationsC-Tick · GOST · UL · CSA · GL
nominal output current5 A
Connections - terminalsScrew terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end · Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end · Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end · Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end
Dielectric test voltage2 kV, 1 min AC 50 Hz
IP degree of protectionIP20 (terminals) conforming to IEC 60529 · IP30 (casing) conforming to IEC 60529
Power consumption in VA0…22 VA at 400 V AC 50 Hz
Switching capacity in VA1250 VA
Control circuit frequency50...60 Hz +/- 10 %
Maximum switching voltage250 V AC
Minimum switching current10 mA at 5 V DC
Product or component typeModular measurement and control relays
Relay monitored parametersPhase sequence · Phase failure detection
Voltage detection threshold< 100 V AC
Product specific applicationFor 3-phase supply
Electromagnetic compatibilityEmission standard for industrial environments conforming to EN/IEC 61000-6-4 · Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 · Immunity for industrial environments conforming to EN/IEC 61000-6-2
[Ui] rated insulation voltage400 V conforming to IEC 60664-1
Control circuit voltage limits- 12 % + 10 % Un
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-20…50 °C
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
What is the difference between on-delay and off-delay timers?

An on-delay timer switches its output after the set time once it receives power or a start signal, while an off-delay timer holds its output on for the set time after the signal is removed. Multifunction timers offer both and other modes such as cyclic and interval.

Which timer do I need for a star-delta starter?

A dedicated star-delta timer has a built-in short dead time between star and delta changeover to prevent a short circuit across contactors. The star time is set to suit how fast the motor reaches near full speed, often a few seconds to around 15 seconds.

What does a phase failure relay protect against?

A phase monitoring relay detects phase loss, phase reversal (wrong sequence) and often phase unbalance or under/over voltage, and trips the contactor coil to protect three-phase motors. It is especially useful for pumps, compressors and lifts where wrong rotation or single phasing can cause damage.

Can I use a timer to run a water pump automatically?

A cyclic or programmable timer can switch a pump contactor on and off at set intervals, but for tank level control a level controller relay with probes or a float switch is more reliable. The pump also needs proper motor protection like an MPCB or overload relay.

Do these mount on DIN rail?

Most modern timers and monitoring relays are DIN rail mounted (35mm), while some older or plug-in types use an 8-pin or 11-pin socket base. Check the mounting type and whether the base is included.

No reviews yet