Schneider Harmony Timer RE17R Timing Relay · 10 functions · 12 V AC/DC · 1 C/O · IP20 · RE17RMJURE17RMJU↓ 40% off1 / 11
BrandSchneider
CategoryIndustrial Control
Specification1 C/O
Brand SKURE17RMJU
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Harmony Timer RE17R Timing Relay · 10 functions · 12 V AC/DC · 1 C/O · IP20 · RE17RMJU

$49.80/pc-40%
$82.98
Wholesale · 15+ units
$47.31 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$49.80 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $47.31/pc on this product, applied automatically

This Harmony RE17R timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 8A, is 17.5mm wide and can be supplied with 12V AC/DC. It also has 1 changeover contact SPDT (single pole double throw). It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Multi function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Harmony Timer RE17R Timing Relay · 10 functions · 12 V AC/DC · 1 C/O · IP20 · RE17RMJU · RE17RMJU
Ingress protectionIP20 (terminal block)· IP40 (housing)· IP50 (front panel)
Reference standard2006/95/EC
Net weight0.07 kg
BrandSchneider
Brand SKURE17RMJU
ELINE2M44RDJ4C
Sold asPer pc
Depth72 mm
Width17.5 mm
Height90 mm
MarkingCE
Function10 functions
Reset time120 ms on de-energisation typical
Control typeSelector switch front panel
Voltage drift+/- 0.2 %/V
Voltage range0.9...1.2 Us
On-load factor100 %
Supply voltage12 V AC/DC
power on delay100 ms
Repeat accuracy+/- 0.5 % conforming to IEC 61812-1
Time delay typePower on-delay · On-delay and off-delay · Interval · Off-delay · Symmetrical flashing
Housing materialPolycarbonate
Mounting support35 mm DIN rail conforming to IEC 60715
Range of productHarmony Timer Relays
Supply frequency50...60 Hz +/- 5 %
Time delay range1...10 s · 6...60 s · 10...100 h · 1...10 min · 1...10 h · 0.1...1 s · 6...60 min
Contacts materialCadmium free
Creepage distance4 kV/3 conforming to IEC 60664-1
Device short nameRE17R
Mounting positionAny position in relation to normal vertical mounting plane
Temperature drift+/- 0.05 %/°C
Tightening torque0.6…1 N.m conforming to IEC 60947-1
breaking capacity2000 VA
Dielectric strength2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
operating frequency10 Hz
Discrete output typeRelay
Electrical durability100000 cycles (8 A at 250 V AC maximum) for resistive load
Insulation resistance100 MOhm at 500 V DC conforming to IEC 60664-1
Mechanical durability10000000 cycles
nominal output current8 A
Connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² (20 AWG...12 AWG) solid without cable end · Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end · Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...14 AWG) flexible with cable end · Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end
Power consumption in VA0…0.7 VA at 12 V AC
Safety reliability dataMTTFd = 296.8 years · B10d = 270000
release of input voltage5 V
Maximum switching current8 A AC/DC
Maximum switching voltage250 V AC
Minimum switching current10 mA at 5 V DC
Product or component typeModular timing relay
[Us] rated supply voltage12 V AC/DC 50/60 Hz
control signal pulse width100 ms with load in parallel typical · 30 ms typical
Contacts type and composition1 C/O
Maximum power consumption in W0.5 W at 12 V DC
Setting accuracy of time delay+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage5 kV during 1.2/50 µs
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
What is the difference between on-delay and off-delay timers?

An on-delay timer switches its output after the set time once it receives power or a start signal, while an off-delay timer holds its output on for the set time after the signal is removed. Multifunction timers offer both and other modes such as cyclic and interval.

Which timer do I need for a star-delta starter?

A dedicated star-delta timer has a built-in short dead time between star and delta changeover to prevent a short circuit across contactors. The star time is set to suit how fast the motor reaches near full speed, often a few seconds to around 15 seconds.

What does a phase failure relay protect against?

A phase monitoring relay detects phase loss, phase reversal (wrong sequence) and often phase unbalance or under/over voltage, and trips the contactor coil to protect three-phase motors. It is especially useful for pumps, compressors and lifts where wrong rotation or single phasing can cause damage.

Can I use a timer to run a water pump automatically?

A cyclic or programmable timer can switch a pump contactor on and off at set intervals, but for tank level control a level controller relay with probes or a float switch is more reliable. The pump also needs proper motor protection like an MPCB or overload relay.

Do these mount on DIN rail?

Most modern timers and monitoring relays are DIN rail mounted (35mm), while some older or plug-in types use an 8-pin or 11-pin socket base. Check the mounting type and whether the base is included.

No reviews yet