Schneider Harmony XB2 Selector Switch · 22 mm · 1 NC + 1 NO · Black · XB2BJ25CXB2BJ25C↓ 40% off1 / 11
BrandSchneider
CategoryIndustrial Control
Specification22 mm · 1 NC + 1 NO · Black
Brand SKUXB2BJ25C
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Harmony XB2 Selector Switch · 22 mm · 1 NC + 1 NO · Black · XB2BJ25C

$6.73/pc-40%
$11.23
Wholesale · 15+ units
$6.60 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$6.73 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $6.60/pc on this product, applied automatically

This Harmony XB2 modular long handle black selector switch has 2 positions, operates with a stay-put mechanism. It's body/ fixing collar is pre-mounted with an NO and an NC contact block. It is easily installed and into a standard 22mm diameter panel cut-outs and connected to control circuits with classic screw-clamp connections. It is clearly distinguishable visually at a distance thanks to its clear color. It is vibration, high pressure washer and dust resistant thanks to its IP65 protection, making it ideal for operation in harsh environments.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Harmony XB2 Selector Switch · 22 mm · 1 NC + 1 NO · Black · XB2BJ25C · XB2BJ25C
Rated current3 A
Ingress protectionIP65
Reference standardIEC 60947-5-1
Net weight0.1 kg
BrandSchneider
Brand SKUXB2BJ25C
ELINE2F4M9GPDF
Sold asPer pc
Depth70 mm
Width45 mm
Height30 mm
Head typeStandard
StandardsIEC 60947-5-1 · IEC 60947-5-4 · IEC 60947-1 · GB/T 14048.1 · GB/T 14048.5
Fixing modeFixing screw beneath head recommended torque: 0.8 N.m · Fixing screw beneath head recommended torque: 1.0 N.m
CustomizableNo
Fixing center>= 30 x 40 mm (panel) - thickness: 1…6 mm
Bezel materialChromium plated metal
Device mountingFixing hole - diameter: 22.5 mm
Operator profileBlack long handle
Range of productHarmony XB2
Type of operatorstay put
Contact operationSlow-break
Contacts materialSilver alloy (Ag/Ni)
Device short nameXB2
Mounting diameter22.5 mm
Tightening torque0.8…1.0 N.m
Operating positionAny position
Device presentationComplete product
Shape of screw headCross compatible with Philips no 1 screwdriver · Cross compatible with pozidriv No 1 screwdriver · Slotted compatible with flat Ø 4 mm screwdriver · Slotted compatible with flat Ø 5.5 mm screwdriver
Overvoltage categoryClass I conforming to IEC 60536
Protective treatmentTC/TH
Electrical durability1000000 cycles, AC-15, 3 A at 240 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C · 1000000 cycles, DC-13, 0.27 A at 250 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability1000000 cycles
Product compatibilityZB2..C
Electrical reliabilityΛ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to IEC 60947-5-4 · Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to IEC 60947-5-4
Fixing collar materialZamak
Connections - terminalsScrew clamp terminal, = 1 x 0.5 mm² with and without cable ends · Faston terminals, connection size: 6.3 mm
IK degree of protectionIK06
IP degree of protectionIP65
Product or component typeComplete selector switch
Cap/operator or lens colourBlack
Shape of signaling unit headRound
Contacts type and composition1 NC + 1 NO
Operator position information2 positions
Sale per indivisible quantity1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
Terminals description ISO n°1(13-14)NO · (21-22)NC
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 · 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-25…70 °C
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
What hole size do these push buttons need?

Most industrial push buttons, pilot lights and selector switches use the standard 22 mm size, which needs a panel hole of about 22.3 mm, while some compact ranges use 16 mm. Check the cut-out size in the product datasheet before punching the panel door.

Which colours should I use for start, stop and indication?

Under IEC 60204-1, red is reserved for emergency stop and must not be used for start; start buttons are white (preferred), grey, black or green, yellow indicates an abnormal condition and blue a mandatory action such as reset. Pilot lights in Indian panels commonly use red, yellow and blue to indicate R, Y and B phase presence.

What is the difference between NO and NC contacts?

An NO (normally open) contact closes when the button is pressed and is used for start; an NC (normally closed) contact opens when pressed and is used for stop and emergency stop. Many push buttons accept additional contact blocks to add more NO or NC contacts.

What is the difference between a maintained and spring-return selector switch?

A maintained (stay-put) selector stays in the selected position, used for modes like Auto/Off/Manual, while a spring-return selector goes back to its default position when released, used for jog or momentary actions.

Is an emergency stop push button different from a normal stop button?

Yes. An emergency stop is a red mushroom head on a yellow background that latches when pressed and needs a twist or key to release, with a positive-opening NC contact (IEC 60947-5-1, IEC 60947-5-5). A normal stop button is momentary and should not be used for emergency stop duty.