Schneider TeSys LC1D Power Contactor · 3P · 95 A AC-3 · 1 NO + 1 NC aux · 24 V DC coil · LC1D95BDLC1D95BD↓ 40% off1 / 5
BrandSchneider
CategoryIndustrial Control
Specification3P · 95 A AC-3 · 1 NO + 1 NC aux · 24 V DC coil
Brand SKULC1D95BD
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider TeSys LC1D Power Contactor · 3P · 95 A AC-3 · 1 NO + 1 NC aux · 24 V DC coil · LC1D95BD

Rating: 95 A AC-3
Coil: 24 V DC coil
$462.56/pc-40%
$770.93
Wholesale · 15+ units
$439.44 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$462.56 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $439.44/pc on this product, applied automatically

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 95A/1000V AC-3/AC-3e (45kW@400V). It provides a 24V DC coil, 1NO+1NC built-in auxiliary contacts, power connections by screw terminals and control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider TeSys LC1D Power Contactor · 3P · 95 A AC-3 · 1 NO + 1 NC aux · 24 V DC coil · LC1D95BD · LC1D95BD
Poles3P (TP)
Rated current95 A
Ingress protectionIP20 front face
Reference standardEN 60947-4-1
coil voltage24 V DC
Net weight2.61 kg
BrandSchneider
Brand SKULC1D95BD
ELINE29DFK93GP
Sold asPer pc
RangeTeSys
Time constant75 ms
Motor power hp7.5 hp at 120 V AC 60 Hz for 1 phase motors · 15 hp at 230/240 V AC 60 Hz for 1 phase motors · 30 hp at 200/208 V AC 60 Hz for 3 phases motors · 30 hp at 230/240 V AC 60 Hz for 3 phases motors · 60 hp at 460/480 V AC 60 Hz for 3 phases motors · 60 hp at 575/600 V AC 60 Hz for 3 phases motors
Motor power kW25 kW at 220/230 V AC 50/60 Hz (AC-3) · 45 kW at 380/400 V AC 50/60 Hz (AC-3) · 45 kW at 415/440 V AC 50/60 Hz (AC-3) · 55 kW at 500 V AC 50/60 Hz (AC-3) · 45 kW at 660/690 V AC 50/60 Hz (AC-3) · 25 kW at 220/230 V AC 50/60 Hz (AC-3e) · 45 kW at 380/400 V AC 50/60 Hz (AC-3e) · 45 kW at 415/440 V AC 50/60 Hz (AC-3e) · 55 kW at 500 V AC 50/60 Hz (AC-3e) · 45 kW at 660/690 V AC 50/60 Hz (AC-3e) · 15
Operating time95...130 ms closing · 20...35 ms opening
Coil technologyWithout built-in suppressor module
Pollution degree3
Protective coverWith
Range of productTeSys Deca Advanced
Average impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit
Device short nameLC1D
Inrush power in W22 W (at 20 °C)
Poles description3P
Tightening torqueControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm · Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 · Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm · Power circuit: 12 N.m - on connector hexagonal screw head 4 mm · Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Compatibility codeLC1D
Control circuit typeDC standard
Overvoltage categoryIII
Utilisation categoryAC-3 · AC-3e · AC-1 · AC-4
Contactor applicationResistive load · Motor control
Electrical durability1.2 Mcycles 95 A AC-3 · 1.3 Mcycles 125 A AC-1 · 1.2 Mcycles 95 A AC-3e
Insulation resistance> 10 MOhm for signalling circuit
Mechanical durability10 Mcycles
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1 · 200 A gG at <= 690 V coordination type 1 for power circuit · 160 A gG at <= 690 V coordination type 2 for power circuit
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 · type mirror contact 1 NC conforming to IEC 60947-4-1
Connections - terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end · Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end · Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end · Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end · Control circui
Rated breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
Pole contact composition3 NO
Safety reliability levelB10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1 · B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Product or component typeContactor
Irms rated making capacity1100 A at 440 V AC for power circuit conforming to IEC 60947 · 140 A AC for signalling circuit conforming to IEC 60947-5-1 · 250 A DC for signalling circuit conforming to IEC 60947-5-1
Power dissipation per pole12.5 W AC-1 · 7.2 W AC-3 · 7.2 W AC-3e
Signalling circuit frequency25...400 Hz
[Uc] control circuit voltage24 V DC
Auxiliary contact composition1 NO + 1 NC
[Ui] rated insulation voltagePower circuit: 1000 V conforming to IEC 60947-4-1 · Signalling circuit: 690 V conforming to IEC 60947-1
Control circuit voltage limits0.1...0.3 Uc (-40…70 °C):drop-out DC · 0.85...1.1 Uc (-40…55 °C):operational DC · 1...1.1 Uc (55…70 °C):operational DC
Hold-in power consumption in W22 W at 20 °C
[Ie] rated operational current95 A (at <60 °C) at <= 440 V AC-3 for power circuit · 125 A (at <60 °C) at <= 1000 V AC-1 for power circuit · 95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Ue] rated operational voltagePower circuit: <= 690 V AC 25...400 Hz
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
[Icw] rated short-time withstand current1100 A 40 °C - 1 s for power circuit · 800 A 40 °C - 10 s for power circuit · 400 A 40 °C - 1 min for power circuit · 135 A 40 °C - 10 min for power circuit · 140 A - 100 ms for signalling circuit · 120 A - 500 ms for signalling circuit · 100 A - 1 s for signalling circuit
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit · 125 A (at 60 °C) for power circuit
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.